1.11 PREvENTION OF dOMESTIC FIRES

The product must be installed and used in compliance with the manufacturer's instructions and European and national standards as well as local
regulations.
a
When a flue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.). See the paragraph "CONNECTION TO THE FLUEWAY".
• It is also recommended that all elements made of combustible or inflammable material, such as beams, wooden furniture, curtaining, flammable
liquids, etc. be kept outside the heat radiation range of the firebox and at a distance of at least 80 cm from the heating block.
• For other information, see the paragraph "MINIMUM SAFETY DISTANCES" and "CONNECTION TO THE FLUEWAY".
• The flue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at least
twice during the seasonal period from the lighting of the firebox and during its use. When the firebox has not been used for some time it is advisable
to carry out the checks mentioned above. For further information, consult a chimneysweep.
• Only use recommended fuels (See section "FUEL").

1.12 MINIMUM SAFETy dISTANCES

Install the product respecting the minimum safety distances from heat
sensitive or flammable materials.
In case of heat sensitive or flammable flooring, it is necessary to install
flame-resistant protection: e.g. steel sheets, marble, tiles, etc.
The minimum safety distances for the stove are (see "TECHNICAL
DATA" table):
A
Stove distance from the rear wall
B
Stove distance from side walls
C
Area clear of flammable objects
D
Floor protection front overhang
Distance between inside edge of fireside opening and the
E
edge of the floor protection
Distance between the smoke outlet from non-flammable
walls.
F
See the technical documentation supplied with the smoke flue
for flammable or heat sensitive walls.
G
Distance between stove and smoke outlet
The flue pipe must respect the minimum distances from building
materials that are heat sensitive or flammable (cladding, beams or
wooden ceilings, etc.) as shown in the figure.
a
The smoke flue must be suitable for connection to a pellet
stove in compliance with the relative national laws in force.
a
Keep any flammable products such as: wood furniture,
carpets, curtains, flammable liquids, etc.. well away from the
stove during operation (minimum 80 cm).
a
We recommend keeping greater distances around the stove
than those displayed in order to facilitate any work on the
appliance and avoid overheating.
12
Fig. 21
F
B
Fig. 22
* = Values refer to the use of original smoke flues; if using other pipes
for the smoke flue, see the documentation supplied with the pipes.
H072058UK0 / DT2001650 – 00
Rear wall
G
A
F
STOVE
G
E
E
C
D
Floor protection
Radiant area of the
fireside opening
Fig. 23
DT2030335-00
DT2010027-02
DT2011553-03
B
DT2033681-01
DT2032226-00