Download Print this page
Sonance Two Zone Connecting Block CB2Z Installation Instructions
Sonance Two Zone Connecting Block CB2Z Installation Instructions

Sonance Two Zone Connecting Block CB2Z Installation Instructions

Two zone connecting block

Advertisement

Quick Links

INSTALLATION INSTRUCTIONS

The Model CB2Z is a device that provides routing of infrared remote control signals. Independent
control of two audio/video systems can be obtained from two zones. One emitter port is provided
for each zone, plus one common port so that certain components can be controlled from both zones.
The CB2Z is a simplified unit, intended for use when only two zones are needed.
CB2Z Two Zone Connecting Block
Fig. 1:
Mounted in 3" SNAPTRACK
(SNAPTRACK is a registered trademark of AUGAT)
C A U T I O N : For Shielded Wire and Long Lead Lengths
When using lengths greater than 200 feet of inter-room shielded cable, it may be
necessary to connect a 470 Ohm 1/8 Watt resistor between I N P U T (SIG) and
G R O U N D (GND) at the IR input terminals of the CB2Z. Refer to Fig. 2, above. The
resistor discharges the cable capacitance more quickly, allowing IR codes of high bit
CB2Z
TWO ZONE CONNECTING BLOCK
S P E C I F I C A T I O N S
• Inputs: 2
• Outputs:Two zone emitter ports and 1
• Can be used with a CB1 Connecting Block or
an ACB1 Amplified Connecting Block for
COMMON emitter expansion. (See Fig. 4 & 5)
• Uses Sonance E1, VE1, E2 and VE2 Mini Emitters.
• Power requirements: 12 volts DC. Uses PS1
o r PS2 Power Supplies.
• 2.1 mm coaxial power jack.
• Dimensions: 2-3/8"W x 3"D x 13/16" H.
®
Fig. 2:
470 Ohm Capacitance
Discharge Resistor
-
Four
screw
removable
connectors to interface with all
3-wire IR receivers (see Caution
Note, Fig. 2, below)
common
emitter
port
(3.5mm
miniature phone jacks).
Pg

Advertisement

loading

Summary of Contents for Sonance Two Zone Connecting Block CB2Z

  • Page 1: Installation Instructions

    • Can be used with a CB1 Connecting Block or an ACB1 Amplified Connecting Block for COMMON emitter expansion. (See Fig. 4 & 5) • Uses Sonance E1, VE1, E2 and VE2 Mini Emitters. • Power requirements: 12 volts DC. Uses PS1 o r PS2 Power Supplies.
  • Page 2 I N S T A L L A T I O N Fig. 3, s e e b e l o w , s h o w s a t y p i c a l t w o - z o n e i n s t a l l a t i o n w i t h a t o t a l o f f o u r r e m o t e r o o m s . A v a r i e t y o f S o n a n c e I R Receivers are shown, two in each zone.
  • Page 3 Power Supply Requirement: 1 . Most IR receivers draw 2 milliamps (mA) without signal and 10 mA with signal (check specs. on actual model). 2 . The maximum current for proper operation from the PS1 Power Supply is 200 ma. 3 .
  • Page 4 Because the Z O N E and C O M M O N jacks on the CB2Z are connected in series, you must CAUTION: have an emitter(s), a connecting block (with emitters), or other Sonance IR controlled device plugged into the COMMON jack for the zone emitters to operate! This is true for the ZONE OUTPUT jack as well.