WARNING: RISK OF FIRE OR EXPLOSION
• Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
• WHAT TO DO IF YOU SMELL GAS:
• Open windows.
• DO NOT try to light any appliance.
• DO NOT operate any electrical switches.
• DO NOT use any telephone in building. Immediately call the
local gas supplier from an outside telephone. Follow the gas
supplier's instructions.
• DO NOT touch any electrical switch; do not use any phone in your
building.
• If you cannot reach your gas supplier, call the Fire Department.
SPECIFICATIONS
Type of Gas: ..............For use with Propane Only
Gas Supply Pressure
to regulator .............Max.: Bottle Pressure
to regulator .............Min.: 20 psig (137.9 kPa)
regulator out ..........20" W.C. (137.9 kPa)
Electrical Input: ..........115V, 60 Hz, 1Ø, 3a
Min. Operating Voltage: 100V
Ignition: .....................Direct Spark
Primary
Flame Control: .........Thermocouple Operated Gas Valve
High Temperature
Control: ...................240°F (116°C)
Min. Ambient Temp. Rating 0°F (-17.8°C)
CONTENTS
WARNINGS ......................................................................... 2-3
HEATER SPECIFICATIONS ..................................................... 3
OPERATING PRECAUTIONS .................................................. 4
SAFETY PRECAUTIONS......................................................... 4
ODOR FADE WARNING ...................................................... 5-6
OPERATING INSTRUCTIONS ................................................. 6
MAINTENANCE, STORAGE AND SERVICE ........................... 7
WIRING DIAGRAMS ............................................................... 8
PARTS LISTS/EXPLODED VIEWS...................................... 9-12
WARRANTY ......................................................................... 13
INSTRUCTIONS FOR ORDERING PARTS ............................ 13
Specifications
Model:
DXH65FAV
Rating:
30,000 - 65,000 Btu/Hr
(8.8 - 19.0 kW)
Fuel Consumption:
1.4 - 2.5 #/hr
(.64 - 1.1 kg/hr)
Fuel Orifice Size
0.50 mm
3
DXH90FAV
50,000 - 90,000 Btu/Hr
(14.6 - 25.0 kW)
2.3 - 3.9 #/hr
(1.04 - 1.77 kg/hr)
0.60 mm