5-3. How to adjust the waveform
<Procedure>
1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture adjustment items as follows.
(1) Picture menu : Standard
(2) Color temperature : Normal
(3) Picture : 25
(4) Aspect : Full
3. Connect Oscilloscope to "TPSC1" and confirm the
initialization pulse.
4. Voltage and waveform adjustments are as follows.
Confirmation Point
Start up of initialization pulse
T2 period
<Location of Test point and Volume>
Volume
Level
VR6601 (SC)
190V (+ -7V)
VR6602 (SC)
165 (+ -10)uSec
(Fig 1)
80uS
Remarks
Fig 1
Fig 2
(SC Board)
TPSC1
VR6602
VR6601
(Fig 2)
190 + -7V
T2