MILK COOLER TEMPERATURE CHECKLIST

Introduction:
This bulletin is to inform the field of basic operational check points related to temperature maintenance
VII. a - TROUBLESHOOTING CHECKLIST
concerns to understand prior to troubleshooting the refrigeration system function.
Below checklist is to inform the field of basic operational check points related to temperature maintenance concerns to
understand prior to troubleshooting the refrigeration system function.
 What is the walk-in cooler/milk storage cooler temp?
Best
Better
33F
36F
39F
 What is the temperature of the milk before it is put into the milk cooler for serving ?
Best
Better
33F
36F
39F
 How long is the serving period?
a
1hr
2hr
(Recommend Doors Closed for at Least 15min for Every 2 hours of Operation.)
 What is the ambient air temperature around the unit?
Best
OK
70F
80F
90F
Bad
 Are there any significant sources of heat around the unit?
 Is there HVAC ventilation directly above the unit or other sources of forced air circulation
that may be disrupting the air flow of the milk cooler?
 With door closed how fast does unit pull down to temperature?
(Depending on the Milk Cooler footprint & loading, it will typically take 15-20 min for the unit to pull down and cycle.)
off)
 Is the milk rotated? If so how often?
(Recommend product is rotated every 2 hours.)
VIII. a - SERVICE CONTACT INFORMATION:
If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service
Contact Traulsen Technical Service:
agent. You may obtain the name of a service agent at:
If further assistance is needed feel free to contact Traulsen Technical Service at 800-825-8220 between
WWW.TRAULSEN.COM/MENU/SERVICE/SERVICE FINDER
the hours of 7:30am – 11:30am CST & 12:30pm – 4:30pm CST.
To speak to Service Support or to purchase Replacement Parts for Traulsen and most Hobart Refrigeration units please
contact our Ft. Worth facility by phone or fax at:
Traulsen
4401 Blue Mound Road Fort Worth, TX 76106 (Monday-Friday 7:30-4:30 CST)
Phone: 800.825.8220
Fax: 817.740.6748 (replacement parts)
Fax: 817.740.6757 (service support)
To obtain other service information, warranty registration or literature please log onto:
WWW.TRAULSEN.COM /MENU/SERVICE
NOTE: When calling Traulsen, please make sure you have model and serial number of unit available.
VII. MILK COOLER TEMPERATURE CHECKLIST
Troubleshooting checklist
OK
Bad
41F
OK
Bad
41F
3hr
4hr
Bad
100F
VIII. SERVICE ASSISTANCE