Shutdown; Data-Size; Table 214 Shutdown Command; Table 215 Data-Size Command - Nokia 7302 Basics, Management And Oam Manual

Intelligent services access manager/fttn/fx, fd 100/320gbps nt and fx nt ihub system
Hide thumbs Also See for 7302:
Table of Contents

Advertisement

"FD 100/320Gbps NT and FX NT IHub System
Basics, Management and OAM Guide"
(2 of 2)
8.12.1.9
Table 214
8.12.1.10
Table 215
Issue: 10
Item
Description
Parameters
domain – Connectivity Fault Management domain
association- Maintenance Association for the Domain
mep - CFM Maintenance Endpoint
session - creates a session for the given mep

shutdown

shutdown command
Item
Description
Syntax
shutdown
Context
configure>eth-cfm>y1731pm>domain
Description
Indicates the desired administrative state of the y1731pm session.
The no form of the command will admin enable the y1731pm session.
Default
Disabled

data-size

data-size command
Item
Description
Syntax
data-size [data-size]
Context
configure>eth-cfm>y1731pm>domain
Description
Specifies the number of octets in the Value field of the Data TLV of the Ethernet CFM packet.
If zero is specified, the packet has no Data TLV.
This parameter is optional and is valid only if type is specified as two-way-slm.
The no form of the command reverts the value to the default.
Default
0
Parameters
data-size — 0...1500
3HH-11982-AAAA-TQZZA