Replacing The Lamp; Closing The Door; Technical Data; Installation - AEG SANTO 60296 DT User Manual

Table of Contents

Advertisement

Available languages

Available languages

Problem

Replacing the lamp

1. Disconnect the mains plug from the mains socket.
2. Remove the screw from the lamp cover.
3. Remove the lamp cover (refer to the il-
lustration).
4. Replace the used lamp with a new lamp
of the same power (the maximum power
is shown on the lamp cover).
5. Install the lamp cover.
6. Tighten the screw to the lamp cover.
7. Connect the mains plug to the mains
socket.
8. Open the door. Make sure that the lamp
comes on.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "Installation".
3. If necessary, replace the defective door gaskets. Contact the Service Center.

Technical data

Dimension of the recess
Rising Time
The technical information are situated in the rating plate on the internal left side of the
appliance and in the energy label.

Installation

WARNING!
Read the "Safety Information" carefully for your safety and correct operation of the ap-
pliance before installing the appliance.
Possible cause
There is no cold air circulation in
the appliance.
Height
Width
Depth
Technical data
Solution
Make sure that there is cold air
circulation in the appliance.
1600 mm
600 mm
645 mm
25 h
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Santo 75338-2dt

Table of Contents