Summary of Contents for Andrew OneBase Cell Extender
Page 1
OneBase™ Cell Extender Model: OBE-DB-X Operation Instruction December 20, 2006 Version. 1.0 Reference Numbers: FCC ID: S8L-OBEMCPA IC:2237F-OBEMCPA Andrew Corporation – Base Station Systems Group Proprietary – Use pursuant to Company Instruction...
25 Watts/carrier (TDMA) 25 Watts/carrier (CDMA) 25 Watts/carrier (GSM/EDGE) DC current draw <140 Amps per Subrack In-Band emissions -13 dBm/MHz Receive Path Noise Figure 3.5 dB Andrew Corporation – Base Station Systems Group Page 1 Proprietary – Use pursuant to Company Instruction...
Page 3
The RF signal is brought into the RFIM, passes into the amplifers, then through the SCM which is blind-mate connected to the amplifiers, and finally into the Filter Modules and subsequent antenna ports. Andrew Corporation – Base Station Systems Group Page 2 Proprietary – Use pursuant to Company Instruction...
Page 4
System Pictures: Front View Rear View Andrew Corporation – Base Station Systems Group Page 3 Proprietary – Use pursuant to Company Instruction...
2. RF Overdrive (> 10 dB) Red: “ON” 3. MCPA high internal temperature (above approximately 90°C). 4. MCPA values indicating: Poor Return Loss (0-3 dB) Andrew Corporation – Base Station Systems Group Page 4 Proprietary – Use pursuant to Company Instruction...
Page 6
Possible Failure Modes Green #1: “ON” Normal Operation NONE Green #2: “ON” Red #1: “ON” Critical Replace Filter Module Red #2: “ON” Critical Replace Filter Module Andrew Corporation – Base Station Systems Group Page 5 Proprietary – Use pursuant to Company Instruction...
Page 7
2. Labeling : OneBase™ Cell Extender subrack when sold in Canada will have: (a) The certification number, prefixed by the term "IC: ", i.e. IC:2237F-OBEMCPA (b) The manufacturer's name, trade name or brand name, i.e. Andrew Corporation (c) A model name or number. Model Name = OneBase™ Cell Extender (d) This device complies with RSS-131, RSS-102 of the IC Rules.
Page 8
426 Watts. In fact, typical usage for various carriers is usually no greater than 50 Watts per carrier (see Specification table). Andrew Corporation – Base Station Systems Group Page 7 Proprietary – Use pursuant to Company Instruction...