Smith Cast Iron Boilers GB100W Installation & Operating Instructions Manual

Natural or propane gas boiler

Advertisement

NATURAL OR PROPANE GAS BOILER
INSTALLATION & OPERATING
DESIGNED AND TESTED ACCORDING TO A.S.M.E. BOILER AND PRESSURE
VESSEL CODE, SECTION IV FOR MAXIMUM ALLOWABLE WORKING PRESSURE OF
NOTE TO INSTALLING CONTRACTOR: READ THESE INSTRUCTIONS CAREFULLY.
THEY WILL SAVE YOU TIME IN ASSEMBLING BOILER PROPERLY.
WARNING: Installation and service must be performed by a qualified installer, service
agency or the gas supplier in accordance with all local and national codes. Failure to
comply with this warning can result in a fire or explosion causing property damage,
personal injury or loss of life!
WARNING: If the information in this manual is not followed
exactly, a fire or explosion may result causing property damge,
personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.
• Do not try to light any appliance.
• Do not touch any electrical switch. Do not use any phone in your
building.
• Immediately call your gas supplier from a neighbor's phone. Follow
the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified in
service agency or the gas supplier.
INSTALLER, THESE INSTRUCTIONS TO BE AFFIXED ADJACENT TO THE BOILER.
CONSUMER, RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PURPOSES.
In Canada: 7555 Tranmere Drive, Mississauga, Ont. L5S 1L4 (905) 672-2991 Fax (905) 672-2883
GB100W
INSTRUCTIONS
50 PSI, 345 kPa WATER
What to do if you smell gas:
WESTCAST, INC.
260 NORTH ELM STREET WESTFIELD, MA 01085
TEL. (413) 562-9631 FAX (413) 562-3799
GB100IOM-7
staller,

Advertisement

Table of Contents
loading

Summary of Contents for Smith Cast Iron Boilers GB100W

  • Page 1 Installation and service must be performed by a qualified in service agency or the gas supplier. INSTALLER, THESE INSTRUCTIONS TO BE AFFIXED ADJACENT TO THE BOILER. CONSUMER, RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE PURPOSES. In Canada: 7555 Tranmere Drive, Mississauga, Ont. L5S 1L4 (905) 672-2991 Fax (905) 672-2883...
  • Page 2: Table Of Contents

    5 page 6 These instructions cover the GB100W gas fired, low pressure, sectional, cast iron hot water boiler. GB100W page 8 boilers have been design certified by CSA under the page 11 latest revision of ANSI-Z21.13 for gas fired low pressure...
  • Page 3: Boiler Ratings & Capacities

    4% for each 1000 ft, 305 m above sea level, 10% in Canada. 2. If ordering a boiler for use with LP gas add a P to the model number, ie PGB100. GB100W NATURAL OR PROPANE BOILER...
  • Page 4 Page 4 6. If the boiler is to be located in an alcove, closet or other confined space the distances from the boiler and it’s vent system to all combustible construction must be equal to or greater than the minimum clearances in Figure 1.
  • Page 5: Combustible Floor Option

    If the GB100W is being installed in an alcove or closet ensure that the minimum distance to combustible construction requirements, listed in Figure 1, are met.
  • Page 6: Chimney & Vent Pipe Connections

    To operate properly and safely this boiler requires a continuous supply of air for combustion. Oxygen is used by the burners in the boiler to burn the gas. In addition, air is also used to assist in the safe disposal of the products of combustion.
  • Page 7 If the damper is damaged or missing do not install the boiler without it! Contact the nearest Smith Cast Iron Boilers distributor to obtain the proper vent damper. WARNING: On boilers with a constant pilot ignition system, ensure that the hole in the damper blade is not plugged.
  • Page 8: Heating System Piping

    The GB100W hot water boiler comes from the factory ready to be piped to the heating system. Each boiler is equipped with a safety relief valve. This valve must be piped in accordance with the ANSI/ASME Boiler and Pressure Vessel Code, Section IV.
  • Page 9 Circulators A TACO 007 circulator has been supplied as standard equipment with the boiler. The 007 is sized for use in a closed heating system with a 30 psi, 207 kPa , maximum operating pressure. If the 007 circulator furnished with...
  • Page 10 Again, the cost of installing the bypass is small and setting it by temperature can be accomplished with a contact thermometer. GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS Figure 8: Pump Away Bypass Pumped Blend An additional circulator can also be used to provide a return water temperature blend.
  • Page 11: Gas Supply Piping

    WARNING can result in extensive property damage, severe personal injury or death! The GB100W hot water boiler comes from the factory ready to be piped to the gas supply. WARNING: Check the boiler rating plate to make sure that the boiler is for the type of gas that will be used.
  • Page 12: Electrical Wiring

    Figure 11. If the test pressure is greater than, or equal to 1/2 psig, 3.5 kPa , disconnect the boiler and it’s individual shut-off valve. GB100W NATURAL OR PROPANE BOILER...
  • Page 13 GB100W NATURAL OR PROPANE BOILER Page 13 INSTALLATION AND OPERATING INSTRUCTIONS Figure 12: Fenwal/Honeywell Direct Ignition...
  • Page 14 Page 14 GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS Figure 13: Honeywell Intermittent Pilot Ignition...
  • Page 15 GB100W NATURAL OR PROPANE BOILER Page 15 INSTALLATION AND OPERATING INSTRUCTIONS Figure 14: Honeywell Continuous Pilot Ignition...
  • Page 16 SIZE ADDITIONAL TRANSFORMER 8VA PER EACH V8043F ZONE VALVE THAT IS REQUIRED. Figure 17: Multi Zone Diagram R8285D POWER SUPPLY GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS Figure 16: Multi Zone Diagram T87F ZONE 3 V8043F END SWITCH...
  • Page 17 ALL of the stated instruction up to this point. Flame Roll-out Safety Shutoff System The GB100W gas boiler is fitted with a flame roll-out switch that detects the presence of hot flue gases in the control compartment. If something prevents the combustion products from property passing through the boiler, the roll-out switch will shut the boiler off.
  • Page 18: Starting The Boiler

    ADJUSTMENT (UNDER CAP SCREW) GAS INLET PILOT RED RESET BUTTON GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS WARNING • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department.
  • Page 19 2. Si un entretien doit être effectué, coupez l'alimentation électrique de l'appareil. 3. Lever le panneau de parte du réchauffer. GB100W NATURAL OR PROPANE BOILER • Si vous ne pouvez rejoindre le fournisseur, appelez le service des incendies. C. Ne poussez ou tournez la manette d'admission du gaz qu'à...
  • Page 20: Operating The Boiler

    1. Set the thermostat to lowest setting. 2. Turn off all electric power to the appliance if service is to be performed. 3. Remove control access panel. GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS VR8304P (Propane Only) VR8305P (Propane Only) smell for gas, including near the floor.
  • Page 21 2. Si un entretien doit être effectué, coupez l'alimentation électrique de l'appareil. 3. Lever le panneau de parte du réchauffer. GB100W NATURAL OR PROPANE BOILER • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suives les instructions du fournisseur.
  • Page 22: Boiler Operation

    Stand clear of the boiler during ignition to prevent being burned in the case of flashback. GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS C. Raise the thermostat at least 5 degrees above the room temperature.
  • Page 23: Checking & Adjusting

    Gas Pressure Adjustment NATURAL GAS: Optimum results are obtained when the boiler is operated at its full input rating, with 3.5 in, 89 mm , WC of manifold pressure. The manifold pressure should not be more that 5% off this value. The gas valve pressure regulator has been preset at the factory.
  • Page 24: Boiler Maintenance

    If the boiler is equipped with a low water cutoff device make sure that the main burners will NOT light when the boiler has no water in it. To check, turn the boiler off, close the valves in the water supply and return lines and drain the boiler.
  • Page 25: Instructions To The Owner

    7. The importance of reading, understanding and following these instructions. The INSTALLER MUST make sure that the owner knows to shut the boiler off and call for service if the following conditions occur: 1. Yellow lazy flames or flames outside the boiler acket.
  • Page 26: Replacement Parts

    REPLACEMENT PARTS Ref # Name of Part Top, Rear, Inner Front and Front Panels Left Side Panel Right Side Panel Floor Pan GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS GB100 SERIES REPAIR PARTS Part No. 55703 55704 55705...
  • Page 27 GB100W NATURAL OR PROPANE BOILER INSTALLATION AND OPERATING INSTRUCTIONS Ref # Name of Part Flue Collector/Drafthood Heat Exchanger/Assembled Block Burner Burner Orifice (#42, NG) Burner Orifice (#54, LP) Manifold High Limit (L4080B-1253) Control Center (R8285D-1026) Spill Switch (262 deg. F) 404257A Rollout Switch (350 deg.
  • Page 28: Canadian Supplement

    Page 28 CANADIAN SUPPLEMENT Only the boiler may be served by the vent damper. Do not use it to vent an additional appliance; this will cause a fire or carbon monoxide poisoning. LE VOLET DE VENTILATION DOIT SERVIR SEULE-MENT À LA CHAUDIÈRE. NE PAS L´UTILISER POUR VENTILER D´AUTRES APPAREILS;...
  • Page 29 First Through Tenth Year Westcast, Inc. warrants that the cast iron sections of its residential water boiler for Smith Cast Iron Boilers were free of defects in material and workmanship when shipped, and will remain free of defects under normal usage from the date of original installation, for a period of ten years.
  • Page 30: Health Warnings

    Carbon Monoxide (CO) is a gas which is odorless, colorless and tasteless but is very toxic. If your Smith boiler is not working properly, or is not vented properly, dangerous levels of CO may accumulate. CO is lighter than air and thus may travel throughout the building. BRIEF EXPOSURE TO HIGH CONCENTRATIONS OF CO, OR PROLONGED EXPOSURE TO LESSER AMOUNTS OF CO MAY RESULT IN CARBON MONOXIDE POISONING.
  • Page 31 GB100W NATURAL OR PROPANE BOILER Page 31 INSTALLATION AND OPERATING INSTRUCTIONS...
  • Page 32 WESTCAST, INC. 260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799...

Table of Contents