Download Print this page
ECA DCP-242V2 Manual

ECA DCP-242V2 Manual

Digiital computerized control panel for 240v ac swing gate motors

Advertisement

Quick Links

DIGIITAL COMPUTERIZED CONTROL PANEL for 240V ac SWING GATE MOTORS
The DCP-242V2 is a universal Control Panel (CP) that can replace any 240V AC control panel for swing gates. It is very simple to
set the timers remotely and to choose the required operating program. The CP has a built-in learning type radio receiver that enables
the end user to teach the CP additional remote controls wirelessly, without the need of accessing the control panel.
Its sensitive rolling code receiver enables to operate the CP with a four-channel (TR-4RS) remote control from a distance of 200m'.
The DCP-242V2 has two options of operating programs from which the user can choose; Automatic or Step By Step.
Capacitor for M1
LIVE - open
AC MOTOR
LIVE - close
1
NEUTRAL
220V live - Input
Neutral - Input
LIVE - open
LIVE - close
AC MOTOR
2
NEUTRAL
Capacitor for M2
Transf.
240V AC
Elc. Lock

Input Terminals:

No.1: + 24V/AC / 60mA; power supply for photo sensor only.
No.2: - 24V/AC
No.3: Common output.
No.4: Common output.
No.5: Optic Sensor Input: Should be connected to Common contacts of an optic sensor.
No.6: PB1; Push Button input for manual operation.
No.7: PB2; Push Button input for pedestrian mode, manual operation.
No. 8: Com.
No. 9: STOP
Optional inputs for Access Control Systems
No.10: CLOSE
supplied upon request.
No.11: OPEN
No 12: contact of the relay output for electric lock or warning light.
No.13: contact of the relay output for electric lock or warning light.

240V AC Power Input:

Terminal No. 19: Should be connected to neutrals 240VAC.
Terminal No. 20: Should be connected to the live voltage; 240V AC 50Hz.
Electrical specifications: Operating voltage: 240V/AC 50Hz.
25
24
PROGRAM
23
22
21
20
240V AC
4A FUSE
19
18
17
16
SW-240 INSTRUCTIONS
ECA Electronic Engineering Pty, LTD.
Australia TEL: 03-95 72 0535
15
14
13
12V AC
12
* This 24V output should NOT be used for an electric lock
Main Fuse
: 5A max / 240V AC.
Model: DCP-242V2
Digital Control Panel
REMOTE
240V AC Swing Gates
TIMER
Model : DCP 242
FUNCTION
FORCE
Jumpers
Push buttons LEDs
Photo Sensor LED
www.gatesonsolar.com
Power Indicator
24V / 0.5A
FUSE
Output load: Max. 1.5Hp 240v/AC.
24V Ac Fuse: 0.5A / 24V AC.
Optional inputs
upon request
N.O.
11
N.O.
10
N.C.
9
Com.
8
BP2
7
BP1
6
Photo Sensor Input
5
Remove bridge when
photo sensor is in use
4
Com.
Com.
3
2
LED
1
OPEN
CLOSE
STOP
N.O.
Pedestrian
N.O.
O/S/C
Photo
Photo
Sensor
Sensor
Rx
Tx
1 2 3 4
5
1
2
N
N
C
+
-
+
-
O
C
M

Advertisement

loading

Summary of Contents for ECA DCP-242V2

  • Page 1 Model: DCP-242V2 The DCP-242V2 is a universal Control Panel (CP) that can replace any 240V AC control panel for swing gates. It is very simple to set the timers remotely and to choose the required operating program. The CP has a built-in learning type radio receiver that enables the end user to teach the CP additional remote controls wirelessly, without the need of accessing the control panel.
  • Page 2 Motors’ Connections: Motor 1 Note – Motor 1 is the motor, which opens first. The output terminals No. 21, 22 and 23 should be connected to the AC Motor 1. The Neutral wire (BLUE) of the motor should be connected to output 21. Connect the live wire of the motor (BLACK), which CLOSES gate to the output terminal 22 and the other live wire of the motor (BROWN), which OPENS gate to the output terminal 23.
  • Page 3 2. HOW TO DELETE ALL THE REMOTE CONTROLS FROM THE CONTROL PANEL’ S MEMORY. 1. Remove the jumper “REMOTE” in the CP. 2. Disconnect the power to the unit. 3. Wait 5 seconds and reconnect the power to the unit. 4.
  • Page 4 Choosing Single or Double swing gates in the control panel This control panel can be used for one single swing gate as well as for double swing gates. In order to select and change the operation to be for a single gate, do as follows: 1.
  • Page 5 How to set these 5 Timers; Before setting the timers in the CP make sure of the following: Motor-1 is installed to the gate that opens first and connected to MOTOR-1 terminals on the Control Panel. • Both motors are opening and closing in the right direction. •...
  • Page 6 Setting Auto Close Time Delay To Increase power by one level With/Without opening delay To Reduce power by one level W/WO PE sensor in opening Manufactured by: ECA Electronic Engineering Pty. Ltd. Australia. 465 Hawthorn Rd. Sth. Caulfield 3162 Vic. Tel:03-95720535 Fax:03-95720536 ecaelectronic@bigpond.com www.gatesonsolar.com...