Specifications

Voltage................................................................................3VDC
Typical average standby current ................................. 35µA
Typical test current........................................................... 2mA
Typical alarm current ..................................................... 70mA
Battery type ................................... Duracell
Low battery threshold........................................2.70V causes
Sounder ................................... 85dBa at 10' temporal pattern
Low battery beep rate .......................1 every 45 sec. ± 2 sec.
Sensitivity ....................................................... 2.2% ± 1.3%/ft.
Operating temperature ..................40° to 100° F (4.4° to 37.8° C)
Operating humidity range .............. 0-95% non-condensing
RFI Immunity ........................... 20V/m minimum; 0-1000MHz
For use with the following panels:
ITI: Advent Commercial Fire 60-562-03 or 60-562-06, with software versions 1.62 and higher

Product Ordering

Model
60-992-900
ESL commercial wireless smoke detector, two 3V lithium batteries, 85dBa sounder,
Accessories
SM-200
SMEXT-1
211
60-933
Patents: 4,855,713 & 4,864,636 & 5,686,885 & 5,686,896 & 6,396,405
www.GE-Interlogix.com
© 2004 GE Security
1039XXX-Rev. PRELIMINARY 09/04
8
®
3V lithium, 123
Panasonic
®
lithium, CR123A
®
Sanyo
lithium, CR123A
low battery signal
Description
thermal, base tamper, 319.5 MHz transmitter
Smoke! in a can
(canned smoke) for functional testing of smoke detectors
Extension tube for Smoke! in a can
Field replaceable optical chambers (set of 10)
6 pack 3V lithium batteries
12345 SW Leveton Drive
Tualatin, OR 97062
Phone: 503-692-4052
USA & Canada: 800-547-2556
Technical Service: 800-648-7424
FaxBack: 800-483-2495
Color .................................................................................white
Alarm dimensions...................... 5.6" x 2.4" (14.2cm x 6.1cm)
Base dimensions ..........................5.4" x 0.96" (13.7cm x 1.17cm)
Drift compensation adjustment ....................... 0.5%/ft. max.
Heat detector specifications:
Rate-of-rise.............................................15° F/min > 105° F
Fixed .................................................................135° F ± 5° F
RF frequency.....................................................902 - 928 MHz
Transmitter ID..................Pre-programmed, 1 Million codes
Modulation type................................................................AM
Signal format....................................................................PWM
Signal output types.............smoke alarm, heat alarm, tamper,
rate-of-rise alarm, test, low battery,
Listing ..................................................... UL268, CSFM, CE, FCC
2266 Second Street North
North St. Paul, MN 55109
www.GE-InterlogixSecurity.com
Phone: 651-777-2690
USA & Canada: 800-777-5484
Technical Service: 800-777-2624
(8.3° C/min > 40.6° C)
(57.2° C ± 2.8° C)