Download Print this page

Waring 6001C IB Instructions Manual page 5

Advertisement

Clean and sanitize motor base prior to initial use and
after each use.
Washing solutions based on non-sudsing detergents and
chlorine-based sanitizing solutions having a minimum chlorine
concentration of 100 PPM are recommended.
The following washing, rinsing, and sanitizing solutions, or their
equivalents, may be used.
SOLUTION
WASHING
DIVERSEY
DIVERSOL
RINSING
SANITIZING
INSTITUTIONAL BLEACH
To Sanitize and Dry Container:
1. Wipe down exterior of juicing assembly with a soft cloth or
sponge dampened with sanitizing solution.
2. Submerge removable components in sanitizing solution
for two (2) minutes.
3. Do not rinse juicing assembly after sanitizing is completed.
4. Allow parts to air-dry.
To Clean and Sanitize Motor Base:
1. UNPLUG POWER CORD. Wipe down exterior surfaces of motor
base with soft cloths or sponges dampened with washing
solution, rinse water, and sanitizing solution. Prevent liquid from
running into motor base by wringing all excess moisture from
cloths or sponges before using them.
DO NOT IMMERSE MOTOR BASE IN WASHING SOLUTION,
RINSE WATER OR SANITIZING SOLUTION.
2. Allow motor base to air-dry before using.
Any other servicing should be performed by an authorized service
representative.
PRODUCT
WYANDOTTE
®
BX/A OR CX/A
®
PLAIN WATER
CLOROX
®
DILUTION IN WATER
4 TABLESPOON
/ GALLON
1 TABLESPOON / GALLON
5
TEMPERATURE
HOT 115°F (46°C)
WARM 95°F (35°C)
COLD 50°F – 70°F
(10°C–21°C)

Advertisement