Mitsubishi EHST20C-VM2C Service Manual page 24

Table of Contents

Advertisement

6-10. EHST20C-TM9C.UK, EHPT20X-TM9C.UK
Power supply
Immersion heater (1Ph3kW)(Option)
to Booster heater
3~ 230V 50Hz
L1
L2
L3
(1)
(3)
(5)
ECB2
ECB1
2 4 6
IHC
1
3
5
A1
BHCP
A2
2
4
6
BHC1
1
3
5
1
3
5
BHC2
A1
A1
2
4
6
A2
2
4
6
A2
IH
2
2
2
BH1
BH2
BHF
BHT
2
1
2
CNBHT
3
(BLK)
1
2
CNBC
3
(GRY)
1
2
3
CNBH
5
2
(WHT)
7
1. S ymbols used in wiring diagram are,
2. I ndoor unit and outdoor unit connecting wires have polarities, make sure to match
terminal numbers (S1, S2, S3) for correct wirings,
3. S ince the outdoor unit side electric wiring may change, be sure to check the
outdoor unit electric wiring diagram for service.
Symbol
Name
TB1
Terminal block <Power supply, Outdoor unit>
ECB1
Earth leakage circuit breaker for booster heater
ECB2
Earth leakage circuit breaker for immersion heater
MP1
Water circulation pump 1(Space heating & DHW)
MP2
Water circulation pump 2 (Space heating for Zone1)(Local supply)
MP3
Water circulation pump 3 (Space heating for Zone2)(Local supply)
MP4
Water circulation pump 4 (DHW)
3WV
3-way valve
2WV2a
2-way valve (For Zone1)(Local supply)
2WV2b
2-way valve (For Zone2)(Local supply)
MXV
Mixing valve (Local supply)
BHT
Thermostat for booster heater
BHF
Thermal fuse for booster heater
BH1
Booster heater 1
BH2
Booster heater 2
BHC1
Contactor for booster heater 1
BHC2
Contactor for booster heater 2
BHCP
Contactor for booster heater protection
IHT
Thermostat (fixed temp.) for immersion heater
IH
Immersion heater
IHC
Contactor for immersion heater
TH1
Thermistor (Room temp.)(Option)
TH2
Thermistor (Ref. liquid temp.)
THW1
Thermistor (Flow water temp.)
THW2
Thermistor (Return water temp.)
THW5
Thermistor (DHW tank water temp.)
THW6
Thermistor (Zone1 flow temp.)(Option)
THW7
Thermistor (Zone1 return temp.)(Option)
THW8
Thermistor (Zone2 flow temp.)(Option)
THW9
Thermistor (Zone2 return temp.)(Option)
THWB1
Thermistor (Boiler flow temp.)(Option)
THWB2
Thermistor (Boiler return temp.)(Option)
IN1
Room thermostat 1 (Local supply)
IN2
Flow switch 1 (Local supply)
IN3
Flow switch 2 (Local supply)
IN4
Demand control (Local supply)
IN5
Outdoor thermostat (Local supply)
IN6
Room thermostat 2 (Local supply)
IN7
Flow switch 3 (Local supply)
IN8
Electric energy meter 1 (Local supply)
IN9
Electric energy meter 2 (Local supply)
IN10
Heat meter (Local supply)
FLOW TEMP. CONTROLLER (FTC5)
TBO.1-4 Terminal block <Outputs>
TBI.1-3 Terminal block <Signal Inputs, Thermistor>
F1
Fuse (T10AL250V)
F2
Fuse (T6.3AL250V)
SW1-5
DIP switch *See 6-19. DIP switch functions.
X1-15
Relay
LED1
Power supply (FTC5)
LED2
Power supply (Main remote controller)
LED3
Communication (FTC5-Outdoor unit)
LED4
Reading or writing data to SD card
CNPWM Pump speed control signal for MP1
CN108
SD card connector
OCH570C
Power supply
to Immersion heater
~/N 230V 50Hz
L
N
(1)
(3)
CNPWM
(WHT)
1
3
3
CNP1
2 4
TBO.1
(WHT)
X1
1
1
M
1~
2
M
MP1
3
X2
3
1~
1
3
5
A1
M
2WV2b
1~
4
X3
MP2
5
M
6
1~
MP3
X14
1
A2
2
4
6
M
1~
3
MP4
CNP4
(RED)
A B
TBO.2
X5A
Close
1
M
N
1~
Open
2
X5B
MXV
3
X4
1
IHT
4
M
1~
5
5
3WV
6
CNV1
(WHT)
TBO.3
X10
1
Signal output
(Boiler)
2
2
X11
3
Signal output
1
CNIH
(Error)
4
3
(ORN)
X12
5
Signal output
(Defrost)
6
X15
Signal output
7
(Comp ON)
8
TBO.4
X13
1
CNIH
M
(ORN)
2
2WV2a
X9
1
3
3
4
X8
5
6
1
3
CNBHT
(BLK)
CNBC
(GRY)
1
3
X6
1
3
X7
5
7
CNBH
(WHT)
: connector,
: terminal block.
Table 1 Signal Inputs
Name Terminal block Connector
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
*1. If using outdoor thermostat for controlling operation of heaters, the lifetime of the heaters and related parts may
be reduced.
*2. To turn on the boiler operation, use the main remote controller to select "Boiler" in "External input setting" screen
in the service menu.
Table 2 Outputs
Name Terminal block Connector
OUT1
OUT2
OUT3
OUT4
OUT5
OUT6
OUT7
OUT9
OUT10 TBO.3 1-2
OUT11 TBO.3 3-4
OUT12 TBO.3 5-6
OUT13 TBO.4 1-2
OUT14
OUT15 TBO.3 7-8
Do not connect to the terminals that are indicated as "—" in the "Terminal block" field.
*1. For 2-zone temperature control.
*2. For 2-zone valve ON/OFF control.
1
<How to use TBO.1 to 4>
2
Connect them using either way as shown below.
4
F1
6
Tool
CN01
F2
(WHT)
Conductor
Outline view
Top view
TBO.1
1
2
3
CNP1
1
(WHT)
4
3
5
6
F2
6.3A 250V
1
1
TBO.2
CNP4
1
(RED)
3
2
3
SW5
4
5
8
LED1
6
1
1
CNV1
TBO.3
1
(WHT)
SW4
5
2
6
3
1
4
5
SW3
6
LED2
7
8
8
1
1
TBO.4
LED3
2
SW2
3
4
8
5
1
1
6
CNIH
(ORN)
3
SW1
1
1
CNBC
CNBHT
8
(GRY)
(BLK)
3
3
1
LED4
CNBH
(WHT)
7
CN1A
CNW5
CNW12
(WHT)
(WHT)
(RED)
1
1
1
2
4
4
2
4
6
8
10
12 14
2
4
6
8
10
12 14
2
4
6
1
3
5
7
9
11
13
1
3
5
7
9
11
13
1
3
5
7
TBI.2
TBI.1
TBI.3
TBI.1
1
2
3
4
5
6
7
8
9
1
2
1
4
1
3
1
2
t
°
t
°
t
°
t
°
t
°
Item
TBI.1 13-14
Room thermostat 1 input
TBI.1 11-12
Flow switch 1 input
TBI.1 9-10
Flow switch 2 input (Zone1) Refer to SW3-2 in <6-19. DIP switch functions>.
TBI.1 7-8
Demand control input
TBI.1 5-6
Outdoor thermostat input *1 Standard operation Heater operation/ Boiler operation *2
TBI.1 3-4
Room thermostat 2 input
TBI.1 1-2
Flow switch 3 input (Zone2) Refer to SW3-3 in <6-19. DIP switch functions>.
TBI.3 1-2
Electric energy meter 1
TBI.3 3-4
Electric energy meter 2
TBI.3 5-6
Heat meter
TBO.1 1-2 CNP1 Water circulation pump 1 output (Space heating & DHW)
TBO.1 3-4
Water circulation pump 2 output (Space heating for Zone1)
Water circulation pump 3 output (Space heating for Zone2) *1
TBO.1 5-6
2-way valve 2b output *2
TBO.2 4-6 CNV1 3-way valve output
TBO.2 1-2
Mixing valve output *1
TBO.2 2-3
CNBH 1-3 Booster heater 1 output
CNBH 5-7 Booster heater 2 output
TBO.4 3-4 CNIH Immersion heater output
Boiler output
Error output
Defrost output
2-way valve 2a output *2
CNP4 Water circulation pump 4 output (DHW)
Comp ON signal
24
Indoor unit powered
Indoor unit powered
by independent source
via outdoor unit
To outdoor
To outdoor
Power supply
unit
~/N 230V 50Hz
Tool
L
N
S1
S2
S3
TB1
L
N
S1
Conductor
BLK
1
BLK
BLK
CN01
2
BLK
(WHT)
4
1
6
1
2
CN01
CN01
2
(WHT)
4
(WHT)
4
F1
6
6
10A 250V
1
CN3C
BRN
BRN
(BLU)
1
1
3
CN3C
CN3C
ORN
ORN
(BLU)
(BLU)
3
3
1
CNPWM
(WHT)
3
CNRF
Wireless receiver
(WHT)
(Option)
CN105
WiFi adapter
(RED)
(Option)
CNIT
(BLU)
CN22
1
(BLU)
2
CN108
CN21
CN20
(YLW)
(RED)
1
1
2
3
8
10
12 14
9
11
13
TBI.3
10
11
12
13
14
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1
2
3
4
5
+ - + - + -
CN22
(BLU)
1
2
t
t
°
°
OFF (Open)
ON (Short)
Refer to SW2-1 in <6-19. DIP switch functions>.
Refer to SW2-2 in <6-19. DIP switch functions>.
Normal
Heat source OFF/ Boiler operation *2
Refer to SW3-1 in <6-19. DIP switch functions>.
Refer to installation manual.
Item
unit
S2
S3
TB1
6
7
8
9
10
11
12
13
14
t
t
t
t
°
°
°
°
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Heating
DHW
Close
Stop
Open
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Normal
Error
Normal Defrost
OFF
ON
OFF
ON
OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents