Appendix B: Recommended Settings For Different Batteries - Planet Networking & Communication BSP-360 Quick Installation Manual

Industrial renewable energy, industrial solar power 5-port gigabit managed switch with 4-port 802.3at poe plus
Hide thumbs Also See for BSP-360:
Table of Contents

Advertisement

Appendix B: Recommended Settings for Different Batteries

We suggest Nickel-cadmium battery and Lead-acid battery for BSP-360. You could
set the Battery type at Battery Management on the web.
Description
Battery type
System voltage
Maximum input voltage
Output voltage for load
Float charge voltage
Absorption charge voltage
LVD (Low Voltage
Disconnection)
LVR (Low Voltage
Reconnection)
Temperature compensation
Baseline@25°C
Battery type
System voltage
Maximum input voltage
Output voltage for load
Float charge voltage
Absorption charge voltage
LVD (Low Voltage
Disconnection)
LVR (Low Voltage
Reconnection)
Temperature compensation
Baseline@25°C
20
Specifications
Nickel-cadmium Battery
24V
45V DC
Equal to battery's voltage
27.2V DC (26.0~30.0V)
29.2V DC (28.0~32.0V)
22.2V DC (21.0~25.0V)
24.8V DC (23.0~27.0V)
±40 mV/°C for NiCad type batteries, Charge
cut-off @ 55°C
Lead-acid Battery (Default Setting)
24V
45V DC
Equal to battery's voltage
27.2V DC (26.0~30.0V)
29.2V DC (28.0~32.0V)
22.2V DC (21.0~25.0V)
24.8V DC (23.0~27.0V)
±60 mV/°C for lead acid type batteries, Charge
cut-off @ 55°C