Peak RF Always

POWER, USER CAL
Function Group
M e n u M a p 5,9
This softkey appears in two locations: the POWER
Tracking Menu
Description
and the USER CAL
Tracking Menu.
The
operation is
the same in
both locations.
This softkey causes the swept CW generator, when in CW or
manual-sweep output mode, to align the output filter (SYTM) so
that its passband is centered on the RF output. Peaking is used to
obtain both the maximum available power and spectral purity, and
the best pulse, FM envelopes, at a given frequency. This peaking
occurs each time the frequency is changed, or every seven minutes.
An asterisk next to the key label indicates this function is active.
SCPI:
CALibration:PEAKing:AUTO
Programming Codes
Analyzer:
Auto Track, Peak RF Once, Tracking Menu
See Also
"Optimizing Swept CW Generator Performance" in Chapter 1