OBJ_BUCH-2413-002.book Page 16 Tuesday, August 30, 2016 12:40 PM
16 | English
– Set up the measuring tool 5 metres away turned by 180° and allow it to
level in.
– Align the height of the measuring tool (using a tripod or by underlaying,
if required) in such a manner that the centre of the laser line is pro-
jected exactly against the previously marked point II on wall B.
– Mark the centre of the laser line as point III (vertically above or below
point I) on the wall A.
– The difference d of both marked points I and III on wall A indicates the
actual deviation of the measuring tool from the level plane.
On the measuring distance of 2 x 5 m = 10 m, the maximum allowable
deviation is:
10 m x ±0.5 mm/m = ±5 mm.
Thus, the difference d between points I and III must not exceed 5 mm
(max.).
Checking the Levelling Accuracy of the Vertical Line
For this check, a door opening is required with at least 2.5 m of space (on
a firm surface) to each side of the door.
– Position the measuring tool on a firm, level surface (not on a tripod)
2.5 m away from the door opening. Allow the measuring tool to level in
while in cross-line operation mode with automatic levelling, and direct
the frontal vertical laser line against the door opening.