1.4.1.2 Installation Steps
1. Attach connection plates, one on each side of the power supplies, using eight pan head screws, eight helical
spring-lock washers and eight plain washers as illustrated in Figure 1.
2. Attach output short plates, one on each pair of terminals, using four flat head screws as illustrated in
Figure 2.
Connection Plate 2U
Plain Washer, No. 10, Stainless Steel
Helical Spring-Lock Washer, No. 10, Stainless Steel
10-32 x 5/16 Pan Head Screw, Stainless Steel
Tightening torque: 25.4-31.7 Lbf-inch (2.87-3.58Nm).
Figure 1: Two 10V Units Connection Plates 2U Assembly
Figure 2: Two 10V Units Output Short Plates Assembly
M3 x 4C Flat Head Screw, Nickel Plated
Tightening torque: 4.7-5.7 Lbf-inch (0.53-0.64Nm)
4
Output Short