Download Print this page

Fan Rotor / Fan Motor - Daikin ATKM50QRV16 Service Manual

Removal procedure, 5.0/6.0/7.1 kw class

Advertisement

Fan Rotor / Fan Motor

8. Fan Rotor / Fan Motor
Warning
Step
1
Remove the 2 screws,
and then the right side
plate.
2
Loosen the screw of the
fan rotor.
3
Remove the fan rotor
from the left groove.
4
Remove the fan motor.
16
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Fan rotor
Right side plate
(R20178)
(R19802)
(R19333)
Fan motor
(R19334)
Si041403EB
Points
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Side face of
Side face of rotor
bottom frame
5 mm (0.2 inch)
(R9582)
(1) Insert the fan motor allowing
for approx. 5 mm (0.2 inch)
of play.
(2) Tighten the fan rotor screw
until it stops. Then give the
screw one more turn.
(3) If the fan rotor rotates
appropriately, tighten the
screw completely.
(4) If not, repeat the procedure
from (1).
Removal Procedure
(R18879)

Hide quick links:

Advertisement

loading