Specification - Haier Smart Power Series Service Manual

Table of Contents

Advertisement

2. Specification

Function
Capacity
Sensible heat ratio
Total power input
Max. power input
AEER or ACOP
Dehumidifying capacity
Power cable
Power source
Running/Max. Running current
Start current
Circuit breaker
Unit model (color)
Type × Number
Speed(H-M-L)
Fan motor input power
Fan
Fan motor output power
Air-flow(H-M-L)
External Static Pressure
Type/Diameter
Heat
exchanger
Total area
Indoor
External (L×W×H)
unit
Dimension
Package (L×W×H)
Drainage pipe (material, I.D./O.D.)
Controller (O-Optional, S-Standard)
Fresh air hole dimension
Electricity heater
Sound power
Sound pressure noise level (H-M-L)
Weight (Net / Shipping)
Type / Charge
Refrigerant
Recharge quantity
Liquid
Piping
Pipe
Gas
Between
MAX.Drop
I.D&O.D
MAX.Piping length
Norminal condition:
Indoor temperature (cooling): 27DB(°C)/19WB(°C), indoor temperature (heating): 20DB(°C)
Outdoor temperature(cooling): 35DB(°C)/24WB(°C), outdoor temperature(heating): 7DB(°C)/6WB(°C)
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity
meter. It is a sound pressure noise level.
Item
Model
ADH105H1ERG/1UH105N1ERG
cooling
kW
10.5(2.5~11.0)
0.74
kW
3.00(0.5~5.3)
W
5300
3.46
-3
3
10
×m
/h
N, V, Hz
A/A
13.3(2.3-23.2)/23.2A
A
A
r/min
850/790/730/720±50r/min(37Pa)
kW
kW
m³/h
pa
mm
2
m
mm×mm×mm
mm×mm×mm
mm
Wired
Infrared
mm
kW
dB (A)
dB (A)
kg / kg
g
g/m
mm
mm
m
m
62
Smart Power
heating
11.5(2.5~12.0)
3.10(0.5~5.3)
5300
3.66
3.2
/
1ph, 220~240, 50/60
13.7(2.3-23.2)/23.2A
/
1Ph, 40A(from outdoor)
ADH105H1ERG
CENTRIFUGALX2
0.27*2
0.17*2
2880/2380/1880/1380
(37Pa-210Pa)
Inner grooved pipe/φ7.0
0.45
1350/490/425
1565/724/510
PVC
YR-E17(S)
YR-HBS01(O)
/
0
59
45/41/37/33
59/70
R410A/2500
45
9.52
15.88
30
50

Hide quick links: