Tamper (cover/external contact)
If a tamper condition does not restore:
Make sure the cover tamper spring is properly installed.
The tamper spring must be properly seated into the switch
post groove.
Figure 9. Tamper spring
Make sure the proper value end-of-line (EOL) resistor is
installed (4700 ohms series resistor).
Figure 10. External contact wiring
Door/Window
Sensor
EOL resistor
Make sure the EOL resistor is properly seated in the
terminal block.
Make sure the terminal block contacts are securely
fastened.
Make sure the external contact wiring meets required
specification.
Open (reed switch/external contact)
If an open condition does not restore:
Make sure the input selection jumper is in the correct
position.
Make sure the arrow on the magnet and the guide line on
the transmitter are aligned and within 3/8 in. (0.95 cm) of
each other.
Verify that the external contact is operating properly in all
conditions of operation.

Specifications

Model number
Brown: 60-362N-11-319.5 (NX-651N)
White: 60-362N-10-319.5 (NX-650N)
Frequency
319.5 MHz
Compatibility
Interlogix 319.5 MHz control panels/receivers
Battery type
3.0 V, 1300 mAh lithium
4
Switch post groove for proper
tamper spring installation
Contacts
4.7 Kohm
Required batteries
Duracell DL 123A, Energizer EL123, Sanyo
CR123A
Estimated battery life
5 to 10 years at 20°C (68°F) depending on
the number of activations per day
Magnet gap
3/8 in. (max.)
Supervisory interval
64 minutes
End-of-line resistor
4.7 Kohm
Typical RF output
0.25mW EIRP
power
Operating temperature
32 to 120°F (0 to 49°C)
Storage temperature
-30 to 140°F (-34 to 60°C)
Relative humidity
0 to 85% noncondensing
Dimensions (LxWxD)
3.02 x 1.5 x 1.02in. (81 x 38 x 26 mm)
Weight
44 g
Listings
UL 1023, UL 634
Replacement plastics
600-1063-60-362N-10
D/W sensor 60-362N-10 - 319..5
replacement enclosure, 5 pack, white
600-1063-60-362N-11
D/W sensor 60-362N-11 - 319..5
replacement enclosure, 5 pack, brown

Regulatory information

Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved
by the party responsible for compliance could
void the user's authority to operate the
equipment.
FCC ID: B4Z-914D-DWS
IC: 1175C-914EDWS

Contact information

www.utcfireandsecurity.com
For customer support, see
support
Copyright © 2011 UTC Fire & Security. All rights reserved.
319.5 Crystal MaxLife Door/Window Sensor Installation Instructions
or
www.interlogix.com
www.interlogix.com/customer-

Advertisement

loading