Download Print this page
AudioCodes SmartWORKS NGX Quick Install
AudioCodes SmartWORKS NGX Quick Install

AudioCodes SmartWORKS NGX Quick Install

All-in-one resource for logging behind a pbx

Advertisement

Quick Links

Using this Reference
This Quick Set-Up Reference is supplementary to
the SmartWORKS User's Guide. It details essential
information about installing a SmartWORKS NGX board
and establishing connectivity between a board, and
customer premises equipment. For information on how
to configure the board, refer to the SmartWORKS User's
Guide that is included on the product CD-ROM.
To identify and locate board hardware such as LEDs, and
audio jack connectors, refer to the information below.
For hardware installation, software installation, and
connectivity between a board, a PBX, and customer
premises equipment, refer to the next page.
NOTE: This unit is for use only with compatible
UL listed PCs or servers.
Agency Approvals
Agency approvals and homologations are available on the
SmartWORKS CD ROM.
LED Descriptions
The SmartWORKS NGX:
CR1: DSP started LED. If the LED is ON, the board downloaded
successfully. This doesn't occur until the first time an application
starts.
CR2: Three stage channel monitoring LED with the following
occurrences:
"GREEN," indicating all channels are connected,
synchronized, and functioning properly.
"AMBER," indicating one or more channels is not
synchronized.
"RED," indicating no channels are synchronized
CR7:TDM clock termination LED. "ON" indicates the boards TDM
clocks are being terminated. The TDM clocks can be terminated
via the control panel.
CR17:Three stage power and board initialization monitoring LED
with the following occurrences:
"ON," indicates that the board has successfully loaded.
"OFF," indicates no communication to the board.
"BLINKING," indicates the board is ready to be
downloaded. After the DLL is loaded the board should
automaticallybe downloaded. If the LED continues to

flash, the board could not be downloaded successfully or
is in a panic state.
Note: Invoking the MTBlinkBoard() API function causes the
LED to blink. The total number of times it blinks equals the
board number + 1. Use this function to match board location
in a chassis with its board number.
System Requirements
The computer must meet the following requirements prior to installing the
SmartWORKS NGX:
Hardware System
Requirements:
· Pentium IV or equivalent 400
MHz or better
· ATX PCI motherboard or
passive backplane with 3.3V
ATX power supply
· PCI 2.2 bus/PCI express
SmartWORKS NGX LEDs
Jumper J8
The SmartWORKS NGX series can be used with an optional 3-pin to
3.5mm adapter.
Installing an MX80 Daughter Card
SmartWORKS NGX Quick Install 402-0006-008
v. 3.10.0
Build 0500507.01 Rev. A
S
WOrKS NGX
mart
Operating Systems:
· Windows 2000 SP 3
· Windows XP SP 1
· Windows 2003 Server 32-Bit
· Linux (Call for availability)
1

Advertisement

loading

Summary of Contents for AudioCodes SmartWORKS NGX

  • Page 1 CR2: Three stage channel monitoring LED with the following Jumper J8 occurrences: The SmartWORKS NGX series can be used with an optional 3-pin to “GREEN,” indicating all channels are connected, 3.5mm adapter. synchronized, and functioning properly. “AMBER,” indicating one or more channels is not synchronized.
  • Page 2 User’s Guide. If no events are generated - verify the following: The computer must be re-booted each time a new AudioCodes board or 1. Use SmartView to look for errors on the line indicating a connectivity issue: SmartWORKS software is installed.