Inhalation of high concentration of refrigerant
vapors is harmful and may cause heart irregu-
larities, unconsciousness, or death. Deliberate
inhalation of refrigerants is extremely danger-
ous. Death can occur without warning. Vapors
reduce oxygen available for breathing and are
heavier than air. Decomposition products are
hazardous. Liquid contact can cause frostbite.
All refrigerant containers, equipment, and
hoses are under pressure.
37880 Series Refrigerant Management System
Specifications
Refrigerants:
Compressor:
Power Source:
Amperage:
Size:
Height:
Width:
Depth:
Weight:
Table of Contents
Section
All Models: R-134a
2-1/2 HP Hermetic Compressors
120V AC 60Hz for US Models
LRA: 30.0
37880
45 inches
19.5 inches
29 inches
Maximum is deluxe unit at 225 lb. with tank
Page Section
2
3
OPTION 7: Refrigerant Management System
4
5
6
Filter change/compressor oil/vacuum oil
6
7
8
9
Repair Parts List
10
Before operating this unit, please read this man-
ual thoroughly. You must understand the proce-
dures outlined in this manual. Failure to follow
these procedures could void all warranties.
Before handling refrigerants, read the material
safety data sheet (MSDS) from the refrigerant
manufacturer.
230V AC 50Hz for CE Models
RLA:
FLA:
LRA: 19.0
2
Page
10
11
12
12
13
14
14
15
16
16