MBT-4000B Multi-band Transceiver System
Serial-based Remote Product Management
Command
Parameter
(Instruction Code
Type
and qualifier)
BUC/BDC
Concise Utility
N/A
MBT
Status
Set RTC (Real-
DAT=mmddyy
All
Time-Clock)
Date
Enable Aux Com
EAM=nm
MBT
Fault Input
Monitoring
Enable
EOM=um
MBT
Online/offline
indicator line
Invert EOM
IOM=um
MBT
Arguments for
Valid on
Command or
MBT or
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
Response to
Query
21 bytes
Query only.
alphanumeric
Returns the utility status of the MBT-4000B Base Unit, response is comma
delimited, in the form aaaa,bbbb where:
aaaa=Physical Address
bbbb=Remote Baud Rate
Example: <0001/CUS?
6 bytes,
Command or Query.
numeric
Sets or returns the date in the form mmddyy, where;
dd=day of the month, from 01 to 31
mm=month of the year, from 01 to 12
yy=year, from 00 to 96 (2000 to 2096)
Example: DAT=042503 would be April 24, 2003.
n=1 AUX COMM
Command or Query.
2=AUX COMM2
EAM controls monitoring of external fault logic inputs to Aux Comm
m=0 (disabled),
connectors (Conn J9 Pin F). If enabled and external fault input is at Logic 1
1 (monitoring
(>2.6 vdc) a fault will be reported. This fault is reported has the LNA I1 or
enabled)
LNA I2 status in the RAS? query
Note: The inputs may be driven by a contact closure relay. They have an
internal pull-up resistor (4.7k) to +5 vdc.
Example: EAM=21
2 bytes,
Command or Query.
alphanumeric
Used to establish Pin G of J9 | AUX COMM to provide Online/Offline
indication in the form um, where:
u=1 (Unit 1) or 2 (Unit 2)
m=O (Letter 'O')=Pin G of J9 | AUX COMM defined as an Output, or
I (Letter 'I')=Pin G of J9 | AUX COMM defined as an Input
1 byte
Command or Query.
This command established the logic level associated with the
Online/Offline indication in the form um, where:
u=1 (Unit 1) or 2 (Unit 2)
m=1 (Invert) or 2 (No invert)
Description of Arguments
between 48 and 57)
>0001/CUS=aaaa,bbbb{cr}{lf}
6–12
MN/MBT4000B.IOM
Query
Response to Command
(Instruction
(Target to Controller)
Code and
qualifier)
N/A
CUS?
DAT=
DAT?
DAT?
DAT*
EAM=
EAM?n
EAM?
EOM=
EOM?
EOM?
IOM=
IOM?
IOM?
Revision 1
Response to
Query
(Target to
Controller)
CUS=x...x
(see Description of
Arguments for
details)
DAT=mmddyy
(same format as
command
arguments)
EAM=nm
(same format as
command
arguments)
EOM=um
(see Description of
Arguments for
details)
IOM=um
(see Description of
Arguments for
details)