Alarm Messages - Toshiba Combi control User Manual

Heat pump control by mobile phone
Hide thumbs Also See for Combi control:
Table of Contents

Advertisement

Alarm messages setup
The Owner can change the default values of the conditions on which alarm messages
are sent. For example, SMS "9713" lowers the room temperature value at which "LOW
TEMPERATURE" SMS is sent from the default 5 °C to 3 °C.
Setup SMS
Response
Combi Control function you activate
command you
SMS format
send
temperature treshold for
91xx*
SETUP
„LOW TEMPERATURE" message
"NO POWER" message blackout
92xx*
SETUP
in hours
"SERVICE" message interval
93xx*
SETUP
in days
* xx marks the place of the numeric value
The
parameters (971) can be between 0-16
„LOW TEMPERATURE"
The
parameters
972) can be between 0-48
"NO POWER"
(
The
parameters (973) can be between 0-360
"SERVICE"
36
When you set parameter 971 to 0, (e.g. you send a text message "9710") then the
controller will not send you a "LOW TEMPERATURE" message.
When you set parameter 972 to 0, then "NO POWER" message will not be sent.
When you set parameter 973 to 0, then "SERVICE" message will not be sent.
Default
values

Alarm messages

Alarm messages are only sent to the Owner.
5 °C
24 h
180 days
Combi Control alarm SMS
Alarm message meaning
e.g. "LOW TEMPERATURE:
Room temperature is low
6 °C" (when the limit is 7 °C)
NO POWER
220V power failure
e.g. "SERVICE: 1 days"
Service date
VERSION
New Owner
Message blackout/
alarm treshold
24h / +5 °C
Default: 24h
Default: 180 days
After setting a new
Owner or changing
Owner
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents