FREESTANDING INSTALLATION, MODELS FS
CLEARANCES TO COMBUSTIBLES (FREESTANDING)
- Side wall to unit
- Back wall to unit
- Corner to unit
- Mantle (Hearth Mount)
-
Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and
front must be protected by a non combustible material.
ALCOVE DIMENSIONS
Minimum Alcove width...........36 inches (900 mm)
Minimum Alcove height .........48 inches (1200 mm)
Maximum Alcove depth .........30 inches (750 mm)
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
A- 6 INCHES (150 mm)
B- 1 INCH
(25 mm)
C- 1 INCH
(25 mm)