6 Default settings

Siemens Switzerland Ltd
Time-out for configuration card
Time-out for display messages 
Activation time-out  
Hold-off time for card read 
Reception for card
Character set   
Min background illumination 
Max background illumination
Bus address
Off-line indication 
Backlight 
Buzzer volume for key press
Buzzer volume for card read 
System sound
Light frame follows LED indicators
Reading MIFARE Classic
Reading MIFARE Plus SL1 – SL3
Reading MIFARE DESFire EV1
The card readers are delivered in this default mode. This mode can be altered with the
Configuration Card Creation Tool (3CT), which enables for required settings to be used
for the card readers. For further information, please contact the supplier of this reader.
The readers use FreeRTOS. For further information, please visit www.freertos.org.
3 seconds
7 seconds
30 seconds
100 milliseconds
Inactive
Windows 1252
12
255
0 (Up to eight are supported)
Yes
Always active (Never and Timed activation are possible)
2
2
10
Red, yellow, green
UID
UID
UID
6   Default settings