H 260E, H 260E eco
2. Assembly, installation, minimum clearance
CAUTION!
Do not install the device directly below a wall
CAUTION!
socket.
The minimum clearances must be observed.
In addition, a clearance of 750 mm is to be maintained
in front of the unit.
The heating device must be aligned horizontally and
installed on a vertical wall (see illustration).
All dimensions in mm
During assembly, the safety area must be complied
with according to the current installation regulations.
The socket or supply connection socket must be
accessible after installation.
Make sure that the inflow and outflow of air at the
device are unimpeded
.
NOTE
NOTE
Installation on wooden walls is permissible.
Wall mounting
CAUTION!
The original wall bracket supplied on the rear
CAUTION!
of the device must be used!
NOTE
NOTE
Look out for electric cables or pipework in the wall
when drilling.
Unlock the wall bracket (A) and remove from the
device.
Drill mounting holes for the wall bracket and insert
the dowels.
Align the wall bracket and firmly screw it onto the
wall.
Hang the device on the wall mount.
Pivot down the heater and push into place (B).
www.dimplex.de/en
3. Electrical connection
The voltage specified on the type plate must match the
line voltage.
The cable must not be in contact with the casing.
It is recommended that a separate circuit be provided
for the power supply.
Insert the plug in the socket. The plug must always be
accessible in case of emergencies.
The unit must be connected only to an earthed power
outlet.
4. Overload protector
For your safety, the heating device is equipped with an
overload protector. If the air circulation is interrupted
(e.g. due to the air grille being covered or closed), the
device switches off automatically. Err35 is shown on
the display.
In this case, the power supply to the heating device
should be disconnected for a few minutes (disconnect
the plug, switch off the fuse) to allow the device to cool
down sufficiently.
Before recommissioning the device, remove the
reasons for the overload protector being triggered.
5. Cleaning
The device must be disconnected from the mains and
allowed to cool down before cleaning and
maintenance. Clean the outside of the device using a
soft, damp cloth. Do not use scouring powder or
furniture polish as this may damage the surface.
Dust which gathers inside the device can be removed
from the outside using a vacuum cleaner.