  • ENGLISH, page 13

Circulating-air mode

An activated carbon filter CLEAN
AIR MODULE must be fitted for this
operating mode
The complete installation set and
replacement filters can be obtained
from specialist outlets. VIB: LZ56700.
The extractor-hood fan extracts the
kitchen vapours which are purified in
the grease filter and activated carbon
filter and then conveyed back into the
kitchen.
The grease filter absorbs the grease
particles in the kitchen vapours.
The activated carbon filter binds the
odorous substances.
If no activated carbon filter is installed,
it is not possible to bind the odorous
substances in the cooking vapours.
Changing the electronic control
systemto recirculating mode:
The standard factory setting is
foroperation in exhaust-air mode.
To change the mode, the extractor
hoodmust have been connected up
andshould be switched off.
Simultaneously press buttons O and
until
comes on. Then release
thebuttons.
goes out shortly afterwards.The
electronic control system will
thenhave been set to recirculating
mode.
By repeating steps 1and 2, you
canchange the electronic control
20
THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.
systemback to exhaust-air mode (
in display).
Caution:
As the filter becomes more and more
saturated with grease, there is an
increased risk of fire and the function of
the extractor hood may be impaired.
Important:
Change the activated carbon filter
promptly to prevent the risk of fire from the
accumulation of heat when deep-fat frying
or roasting.
Saturation indicator:
When the activated carbon filter becomes
saturated, the display symbol
and a signal sounds. The signal is
switched off when the fan is switched off.
The activated carbon filter should be
replaced straight away.
Replacing the activated carbon filter:
During normal operation (1 to 2 hours
per day) the activated carbon filters
should be replaced approximately 1 x
year.
A replacement filter can be obtained
from any authorized dealer.
Use original filters only.
By doing so you will obtain maximum
performance from your extractor hood.
Disposing of the old activated carbon
filter:
There are no pollutants in the
activated carbon filters. They can
therefore be disposed of as part of
your normal domestic refuse.