Other Cords - Brother S-7100A Basic Operation Manual

Single needle straight lock stitcher with thread trimmer
Hide thumbs Also See for S-7100A:
Table of Contents

Advertisement

Available languages

Available languages

1. INSTALLATION

1-4-2. Other cords

For Europe specifications, Americas 220V specifications and 100 V/400 V system specifications, connect the cords according
to the respective specifications.
<Seen from underneath table>
7
Control box
Green and yellow wire (ground wire)
S-7100A
< Europe specifications >
(1) Filter box
(2) Screws [4 pcs]
(3) Connector
(4) CE bush plate
(5) Screws [2 pcs]
(6) CE D cord cover
(7) Screws [2 pcs]
(8) Staples [5 pcs]
(9) Power cord
1. Attach an appropriate plug to the
power cord (9). (The green and
yellow wire is the ground wire.)
2. Insert
properly-grounded electrical outlet.
[NOTE]
・ Take care when tapping in the
staples (8) to make sure that they
do not pierce the cords.
・ Do not use extension cords,
otherwise
problems may result.
Leg
0486D
the
power
plug
into
machine
operation
a

Advertisement

Table of Contents
loading

Table of Contents