Download Print this page

Bungard Compacta L30 Instructions For Use Manual

Plating line

Advertisement

Quick Links

Compacta L30
Instructions for use
Bungard Elektronik ·GmbH&Co KG· Rilke Str. 1 · D-51570 Windeck
Tel 02292 5036 · Fax 6175 · info@bungard.de
Plating line
Contents
Safety instructions
Appendices:
Electrical circuit
Chemistry Set-Up
Process Flow Table
Plating System Steps descriptions
Safety instructions
1. General
Do not use the appliance for any other
application than through hole plating
of PCB material. Read all safety in-
structions and all operating instruc-
tions thoroughly before using the unit
for the first time.
Keep these safety instructions and ope-
rating instructions somewhere safe in
case you need to refer to them again in
the future.
2. Safety warnings
In your own interest pay attention to
all safety warnings on the unit and in
the operating instructions. Follow the
instructions on operation and use of
1
the unit in every respect.
2
3. Ventilation
3
Wherever you put the unit, always en-
sure there is sufficient ventilation. An
3
exhaust system may be necessary de-
3
pending on your local requirements.
4
4. Heat and moisture
4
To prevent fire or the risk of electric
shock, keep this unit out of the rain and
6
away from moisture. Do not place the
7
unit close to sources of heat like radia-
tors or hot air shafts.
5. Electric power
To avoid the risk of electric shock, do
not remove the housing and do not
open the back. There are no user ser-
viceable parts inside.
Page 1

Advertisement

loading

Summary of Contents for Bungard Compacta L30

  • Page 1: Table Of Contents

    Process Flow Table open the back. There are no user ser- Plating System Steps descriptions viceable parts inside. Bungard Elektronik ·GmbH&Co KG· Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 2 In the event of accidents or feeling un- ting instructions. well always consult a doctor. Bungard Elektronik GmbH&Co KG· · Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 3: Equipment

    3 remove all cloth fuzzles and rinse the like copper, observe the local regulati- tank walls and ground with deminera- ons. lized water. Bungard Elektronik ·GmbH&Co KG· Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 4: Spare Parts

    3.1 The heater switch button is lighted. Refer to the Plating System Step docu- Press heater button and adjust tempe- mentation in the appendix for details. rature: Bungard Elektronik GmbH&Co KG· · Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 5 Bath 6: Copper plating sing step in order to avoid contaminati- Fix both anodes to the anode holders, on of the following treatment bathes. Bungard Elektronik GmbH&Co KG· · Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 6: Through Hole Plating Process Sequence

    A / dm² x 2 sides at 6 dm² = 3 x 2 x 6= not rinse after Pre-Dip but you have to 36 A. go directly to the following bath 3! Bungard ElektronikGmbH&Co KG· · Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...
  • Page 7: Replenishment/Bath Maintenance

    A / dm² x 2 sides at 6 dm² = 3 x 2 x 6 (C) 6/2002 Bungard Elektronik = 36 A. Bungard Elektronik GmbH&Co KG· Rilke Str. 1 · D-51570 Windeck Tel 02292 5036 · Fax 6175 · info@bungard.de...