Pentair Pool Products IntelliChlor PC100 Installation And User Manual

Pentair Pool Products IntelliChlor PC100 Installation And User Manual

Advertisement

®
IntelliChlor
Power Center
(For use with IntelliChlor
model IC60, IC40 and IC20)
Patents
pending
Installation
Certified to NSF/ANSI 50
and
User's Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
IntelliChlor Power Center Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Pentair Pool Products IntelliChlor PC100

  • Page 1 ® IntelliChlor Power Center (For use with IntelliChlor model IC60, IC40 and IC20) Patents pending Installation Certified to NSF/ANSI 50 User’s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IntelliChlor Power Center Installation Guide...
  • Page 2: Table Of Contents

    Technical Support Sanford, North Carolina (8 A.M. to 5 P.M. ET) Moorpark, California (8 A.M. to 5 P.M. PT) Phone: (800) 831-7133 Fax (800) 284-4151 Web sites: visit www.pentairpool.com and staritepool.com Contents IMPORTANT SAFETY PRECAUTIONS ............i IntelliChlor Power Center Overview ..............1 IntelliChlor System Components ..............
  • Page 3: Important Safety Precautions

    WARNINGS AND IMPORTANT SAFETY PRECAUTIONS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS AND POOL OPERATORS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PUMP AND SAND FILTER. To reduce the risk of injury, service should only be done by a qualified pool service professional.
  • Page 4 WARNINGS AND IMPORTANT SAFETY PRECAUTIONS Never operate the IntelliChlor Electronic Chlorine Generator (IECG) without proper flow or water circulation. A build-up of flammable gases will result in hazardous conditions. Operate unit with minimum flow of 25 gpm. For high flow applications, use a bypass loop.
  • Page 5 WARNINGS AND IMPORTANT SAFETY PRECAUTIONS For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety Commission at (301) 504- 7908 or visit www.cpsc.gov. NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
  • Page 6: Intellichlor Power Center Overview

    ® IntelliChlor Power Center Overview The IntelliChlor electronic chlorine generator system comprises of a Power Center and electrolytic Cell. The Power Center converts AC electrical current to a low voltage DC current required by the IntelliChlor electrolytic cell to operate and create chlorine for the swimming pool and spa.
  • Page 7: Intellichlor System Components

    IntelliChlor System Components An IntelliChlor Electronic Chlorine Generator IntelliChlor system consists of one or more of the following: • PC100 (P/N 520556): Power Center Kit. Provides power and control communication to and from theIntelliChlor cell. • IC20 Cell (P/N 520554): Designed for pools up to 20,000 U.S. gallons (75,000 liters). The cell willproduce the equivalent of 0.70 lbs.
  • Page 8: Installing The Power Center

    Installing the Power Center IMPORTANT SAFETY PRECAUTIONS. PLEASE READ THE FOLLOWING: Read all the safety precautions in this manual before attempting any electrical wiring. Be sure to read and follow all safety Instructions on page ii. Wiring should only be performed by a qualified professional.
  • Page 9 Preparing the SiteMount the Power Center enclosure Remove the screw securing the Power Center cover and remove the cover. Mount the Power Center on a flat surface such as a wall or post and mark each mounting bracket screw hole location. There are two (2) screw holes and a keyslot for the top and lower bracket.
  • Page 10 ® Connect AC Power to the IntelliChlor Power Center Use 12-14 AWG three conductor insulated wire for the main AC power connection. Connect the Power Center to pool pump AC power source. The Power Center should be connected to the pump motor switch or automatic timer. For system wiring information, see page 6.
  • Page 11: Troubleshooting

    Troubleshooting Note: Turn off power to unit before attempting to service or repair. l l e g i l y f i v i t y f i Electrical Specifications Circuit Protection: Two-pole 20 AMP device at the electrical panel. IntelliChlor Model IC20 Input: 90-130 VAC, 50/60 Hz, 220 Watts (2 AMP) or 220-240 VAC, 50/60 Hz, 220 Watts (1 AMP).
  • Page 12: 230 Vac Basic System Wiring

    110 VAC and 220 VAC Transformer Wiring 115 VAC Basic System Wiring 230 VAC Basic System Wiring IntelliChlor Power Center Installation Guide...
  • Page 13 IntelliChlor Power Center 230 VAC and 115 VAC Transformer Wiring IntelliChlor Power Center Installation Guide...
  • Page 14 LIMITED WARRANTY ® Pentair Water Pool and Spa, Inc. ("Pentair") warrants the IntelliChlor Electronic Chlorine Generator (IECG) as follows: IECG Cell Limited Warranty: Pentair warrants the IECG to be free from defects in material and/or workmanship for a period of one (1) year from the original date of installation. IECG Power Center Limited Warranty: Pentair warrants the IECG Power Center to be free from defects in material and/or workmanship for a period of one (1) year (parts only) from the original date of installation.
  • Page 15 PLEASE NOTE: Some states do not allow the exclusion or limitation of incidental, or consequential damages, so the above limitation or exclusion may not apply to you. No Other Warranties: TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, PENTAIR DISCLAIMS ALL OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
  • Page 16 *520590* P/N 520590 Rev D IntelliChlor Power Center Installation Guide...