Download Print this page

Siemens CC-5 Installation Instructions Manual

System cardcage

Advertisement

Quick Links

Installation Instructions

Models CC-5 / CC-2
System Cardcage
INTRODUCTION
OPERATION
P/N 315-033035-6
The Model CC-5 Cardcage from Siemens Industry, Inc., (see Figure 1) has five card
slots and occupies two positions on the studs in the backbox or on the optional CAB-
MP Mounting Plate. The Model CC-2 Cardcage (see Figure 2) has two card slots and
occupies one position on the studs in the backbox or on the optional CAB-MP
Mounting Plate. The CC-5 and CC-2 are used for mounting all system circuit card
assemblies. They each have two removable terminal block connectors at the top and
one removable terminal block connector at the bottom of each card slot. All field-
wiring connections are made directly to the top of the cardcage while internal power
is connected to the bottom of the cardcage. The two removable terminal block
connectors at the top of each slot are arranged in two rows. The lower row is labeled
1 through 8 and the upper row is labeled 9 through 16. These removable terminal
block connectors are used for connecting power limited external equipment. The
removable terminal block connector located at the bottom of each slot is labeled 17
through 24 and is used for connecting internal power.
Note:
Boards shown without card guides installed.
Figure 1
CC-5 Card Cage
The CC-5 and CC-2 provide a central point for mounting circuit card assemblies. If a
card requires power, it is applied through the removable terminal block at the bottom
of the cardcage. All external devices for the card are connected to the card through
the two removable terminal blocks at the top of the cardcage. The circuit card
assemblies are connected to the HNET and CAN bus through the connectors on the
cardcage.
Figure 2
CC-2 Card Cage
Siemens
Siemens Industry
Siemens
Industry
Industry, , , , , Inc.
Siemens
Siemens
Industry
Building
Building
Building
Building
Building T T T T T ec
ec
ec
echnologies Di
ec
hnologies Division
hnologies Di
hnologies Di
hnologies Di
Industry
Inc.
Inc.
Inc.
Inc.
vision
vision
vision
vision

Advertisement

loading

Summary of Contents for Siemens CC-5

  • Page 1: Installation Instructions

    CC-2 Card Cage OPERATION The CC-5 and CC-2 provide a central point for mounting circuit card assemblies. If a card requires power, it is applied through the removable terminal block at the bottom of the cardcage. All external devices for the card are connected to the card through the two removable terminal blocks at the top of the cardcage.
  • Page 2: Pre-Installation

    PRE-INSTALLATION The CC-5 and CC-2 are shipped with the card guides removed. The card guides are keyed to assist in installation. They can be installed either before or after the cardcage is installed in the enclosure. For ease of installation, the card guides have been designed to be installed after the field wiring has been completed.
  • Page 3 CC-5 and another 1-position module (i.e., PSC-12). It is best installed in a position adjacent to the CC-5. When only one CC-5 cardcage is to be installed, it is normally installed on the left side of a row in the backbox or on the Mounting Plate.
  • Page 4 CC-5 BOTTOM THREADED POSTS CC-2 BOTTOM THREADED POSTS POSITION 1 POSITION 2 POSITION 3 POSITION 4 Figure 4 Location Of The CC-5 and CC-2 On The Optional CAB-MP SLIDE DOWN CARDCAGE UNTIL FLUSH ON TOP, LEFT, AND BOTTOM CC-5 CC-2 CARDCAGE CARDCAGE...
  • Page 5 WIRING At the top and bottom of the CC-5 and CC-2 and adjacent to each card slot are removable terminal blocks. The wiring to the two terminal block connectors at the top of the CC-5 and CC-2 is power limited. The wiring to the terminal block connector at the bottom of the CC-5 and CC-2 is non-power limited.
  • Page 6 (FMT). The connector is keyed and requires no special instructions for cable connec- tion. Use cable CCL, P/N 500-634214 to connect from CAN bus (P3) on CC-5 and CC- 2 to the desired module. CAN power must be supplied to E11 (CC-5) or E5 (CC-2) Refer to Figure 8 for wiring details.
  • Page 7: Specifications

    4.78”W x 14.25”H Electrical Ratings: The PSC-12 supplies the power to the two 60-pin Data bus connectors (P1 and P2) in the CC-5 and CC-2. The total rating on P1 and P2 for all CC-5s in any given enclosure is as follows:...
  • Page 8 Cyber security disclaimer Siemens products and solutions provide security functions to ensure the secure operation of building comfort, fire safety, security management and physical security systems. The security functions on these products and solutions are important components of a comprehensive security concept.

This manual is also suitable for:

Cc-2