MAIN SET ONE POINT REPAIR GUIDE
1-3. NO BOOTING WHEN YOU TURN THE UNIT ON, NO MESSAGE OR "PLEASE
WAIT" ON FRONT PANEL
When you turn on your set, it will blank / no message or "PLEASE WAIT" display on front panel,
and it will not boot-up.
1-3-1. D101 (NO 3.3 VA)
1-3-1-1. Solution
Replace D101 on MAIN board.
1-3-1-2. How to troubleshoot (Countermeasure)
1) Please check 3.8 VA(yellow signal).
2) If 3.8 VA is abnormal, please check SMPS board.
3) If 3.8 VA is OK, but 3.3 VA is abnormal, replace D101.
1-3-1-3. Service hint (Any picture / Remark)
D101
IC101
< MAIN board top view >