Code
Type
Causes
What To Do
0
Operation
Program select was selected when
Reset and position cursor.
the cursor isn't at the beginning of
the field.
RIGHT ADJ was pressed not in a
Reset and press correct key.
right adjust field except at the end
of the record.
SKIP, DUP, or REC ADV was pressed
Reset and position cursor.
in a right adjust field and not at the
first position of the field.
SKIP, DUP or REC ADV was pressed
Reset and position cursor.
in a self-check field and not at the first
position of the field.
DISPLAY FIELD TOTALS was
Reset and position cursor.
pressed not at the beginning of the
field.
DISPLAY PROD STAT was attempted
Reset, selection program 0 and reselect
not under program level zero or in
function.
enter (E) mode and the data had
been entered into the current record.
P
Program
The key following SEL PROG or PROG
Reset and rekey sequence.
LOAD isn't a program number.
A new program was selected while
Reset and position cursor on field beginning
not at
a
field begin character.
or change program.
Incorrect Program was selected.
Reset and modify program or reselect
program.
Q
Field totals
No . (period) or digit follows the
Reset and rewrite the control statement.
program character.
The position number is greater than
Reset and rewrite the control statement.
80 for the 3742 or 128 for 3741 or
3742 with 128 feature.
No N or W follows the position number. Reset and rewrite the control statement.
An invalid character follows the mask
Reset and rewrite the control statement.
(must be ,;:.&).
Program 1 through 6 on 3742 or 1
Reset and rewrite the control statement.
through A on the 3741 or 3742 with
128 feature is not specified in the
mask statement.