Function and Functional Testing
Digital Inputs:
Configuration Mode:
Normal Operation Mode
Siemens Building Technologies
Fire & Security Products
LED green:
Activates the green LED while the input is switched to ground
LED red:
Activates the red LED while the input is switched to ground
Beeper:
Activates the beeper while the input is switched to ground
Hold:
While input "Hold" is switched to ground the reader doesn't accept
any Transponder
After the power supply is switched on the reader starts his configuration mode for 8
seconds. The configuration mode is indicated by alternating blinking of the red and
green LED.
While the configuration mode is active the reader could be configured with a spe-
cial ConfigCard. In this mode the reader accepts only ConfigCards. Please contact
your supplier to get further information's about ConfigCards.
After the configuration modes has finished the reader changed into the normal op-
eration mode.
In the normal operation mode the LED and the beeper are controlled by the digital
inputs.
When the reader detects a transponder the data where send out at the clock/data
interface and the beeper indicates the detection with a short single beep nonrecur-
ring.
To repeat this a read action the transponder must leave the detection range of the
reader for more than 1,5 seconds.
If the Transponder data length doesn't match to the reader configuration the
beeper indicates an error by a short double beep. In the case no data's are send
out at the clock/data interface.
7
AR6111-MX-Manual.doc
02.2003