Computer environment

Airborne contaminant level: G2 or lower as defined by ISA-S71.04-1985
Temperature range
Relative humidity
(maximum)
Vibration
*
(maximum)
Shock (maximum)
Altitude (maximum)
* Measured using a random vibration spectrum that simulates user environment.
† Measured using a 2 ms half-sine pulse when the hard drive is in use.
12
Operating
5°C to 35°C (41°F to 95°F)
10% to 90% (non-
condensing)
0.26 GRMS
40 G for 2 ms with a change
in velocity of 20 in/s (51
cm/s)
–15.20 m to 3048 m (–50 ft
to 10,000 ft)
Storage
–40°C to 65°C (–40°F to
149°F)
0% to 95% (non-condensing)
1.37 GRMS
105 G for 2 ms with a change
in velocity of 52.5 in/s (133
cm/s)
–15.20 m to 10,668 m (–50 ft
to 35,000 ft)