2.10.6.2
Nonoperating shock
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 800 Gs based on a nonrepetitive half-sine shock pulse
of 2 msec duration.
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 1,000 Gs based on a nonrepetitive half-sine shock
pulse of 1 msec duration.
The nonoperating shock level that the drive can experience without incurring physical damage or degradation
in performance when subsequently put into operation is 600 Gs based on a nonrepetitive half-sine shock pulse
of 0.5 msec duration.
2.10.7

Vibration

All vibration specifications assume that the drive is mounted securely with the input vibration applied at the
drive mounting screws. Vibration may be applied in the X, Y or Z axis.
2.10.7.1
Operating vibration
The maximum vibration levels that the drive may experience while meeting the performance standards speci-
fied in this document are specified below.
5–500 Hz
1.0 Gs (0 to peak). Max displacement may apply below 10 Hz.
2.10.7.2
Nonoperating vibration
The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degrada-
tion in performance when subsequently put into operation are specified below
5–500 Hz:
5.0 Gs (0 to peak). Max displacement may apply below 22 Hz.
2.11

Acoustics

Drive emission of sound is measured consistent with the ECMA-74 and its referenced standards. Testing is
conducted at room temperature (approximately 25
sound power levers for steady state, idle, and active seeks modes of operation.
Table 5:
Drive A-weighted Sound Power Levels (SWL, BA)
Idle*
Performance seek
2.3 bels (typ)
2.6 bels (typ)
2.5 bels (max)
2.7 bels (max)
*During periods of drive idle, some offline activity may occur according to the S.M.A.R.T. specification, which may increase acoustic and
power to operational levels.
Test for Prominent Discrete Tones (PDTs)
Seagate follows the ECMA-74 standards for measurement and identification of PDTs. An exception to this pro-
cess is the use of the absolute threshold of hearing. Seagate uses the lower limit for the threshold curve* to
discern tone audibility and to compensate for the inaudible components of sound prior to computation of tone
ratios according to Annex D of the ECMA-74 standards.
*Defined as the median curve given by ISO 389-7 (Tf curve) minus 10dB at all frequencies.
12
.
C). Emission levels are reported as the total A-weighted
°
Momentus 7200.3 SATA Product Manual, Rev. B

Advertisement

Table of Contents
loading

Table of Contents