Charging Battery Removed From The Vehicle - Schumacher SCF-2500A SpeedCharge Owner's Manual

Fully automatic microprocessor controlled battery charger with battery tester for 12-volt batteries
Table of Contents

Advertisement

Available languages

Available languages

CHARGING BATTERY REMOVED
FROM THE VEHICLE:
POSITIVE
BATTERY
1. Note the polarity of the battery posts
by checking the identification marks
on the battery: POSITIVE (POS, P or
+) and NEGATIVE (NEG, N or -). The
positive post is usually larger than
the negative post.
2. Attach at least a 24-inch-long, 6-
gauge (AWG), insulated battery
cable to NEGATIVE (NEG, N or -)
battery post. Rock and twist the
clamp back and forth to be sure a
solid electrical connection is made.
3. Connect the red (POSITIVE) output
clamp to the POSITIVE battery post.
Rock and twist the clamp back and
forth to be sure a solid electrical
connection is made.
4. Position yourself as far away from
the battery as possible, and then
connect the black (NEGATIVE)
output clamp to the free end of the
cable.
5. Plug the power cord into an AC
outlet. The charger will be set to the
Tester Mode for REGULAR battery
type.
NEGATIVE
24", 6 GAUGE CABLE
BATTERY CHARGER
POWER
CORD
TO
GROUNDED
POWER
OUTLET
6. Press the appropriate control buttons
to select the desired charge rate and
battery type. The CHARGING
(yellow) LED should light and the
charging process should start. If the
CHECK (red) LED is on, check for
correct cable connections.
7. To disconnect the charger, unplug its
power cord before attempting to
disconnect the charger clamps. Then,
standing away from the battery,
remove the output clamp from the
NEGATIVE battery post. Finally,
remove the output clamp from the
POSITIVE battery post.
8. Clean and store the charger in a dry
location.
IMPORTANT: Follow all safety instruc-
tions and precautions when charging
your battery. Wear complete eye
protection and clothing protection.
Charge your battery in a well-ventilated
area.
7

Advertisement

Table of Contents
loading

Table of Contents