11-3. MUZ-GL24NA MUZ-GL24NAH MUY-GL24NA
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws of the service panel.
(2) Remove the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove the screws fixing the conduit cover.
(6) Remove the conduit cover.
(7) Remove the top panel.
(8) Remove the valve cover.
(9) Disconnect the power supply and indoor/outdoor con-
necting wire.
(10) Remove the screws of the cabinet.
(11) Remove the cabinet.
(12) Remove the screws of the back panel.
(13) Remove the back panel.
Photo 2
Screws of the
top panel
Screws of
the back
panel
Screws
of the
cabinet
Screws of the
back panel
OBH733D
Screws of the
back panel
Screws of the
back panel
Screws of
the service
panel
Screw of
Screws of
the valve
the back
cover
panel
NOTE: Turn OFF the power supply before disassembly.
Photo 1
Screws of the top panel
Screws
of the
cabinet
Screws of the
cabinet
Photo 3
Screws of the conduit cover
Photo 4
Screw of the conduit plate
71
PHOTOS
Screws of the