6.7 Time aggregation mode
The time aggregation mode is a special USB streaming mode, which reduces the frame rate compared to the sampling rate of
the sensors. Measurements are aggregated in time frames and then the minimum, maximum, mean and standard deviation
of these time frames are reported.
Currently, the CISS contains a fixed configuration for the time aggregation mode:
Acceleration & angular velocity, sampling rate 100Hz, time frame 2s
Temperature, sampling rate 1Hz, time frame 10s
See chapter 7 for the format of the signaled USB messages.
INFO: When entering the time aggregation mode, the BLE functionality of the CISS is completely
switched-off (i.e. the CISS will no longer advertise).
7 Usage of the communication interfaces
For a detailed description regarding the communication interfaces, please refer to the following documents:
CISS BLE Communication Protocol
CISS USB Communication Protocol
These documents are available at:
8 Maintenance
Warning: Damage to materials can cause risk of fire!
Liquid which enters the device can cause short circuits and damage the device.
This could cause fire, data loss and incorrect measurements.
9 Further Product Related Information
Please find all product related documents and user guides on our website:
www.bosch-connectivity.com/media-and-downloads
Please click on "Load more" to see all available documents.
www.bosch-connectivity.com/media-and-downloads
24