Summary of Contents for Omega OM-CP-OM-CP-OCTPRO

  • Page 1 User’s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info OM-CP-OCTPRO Portable Data Acquisition Logger...
  • Page 2 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.
  • Page 3: Table Of Contents

    PRODUCT OVERVIEW Device Overview TABLE OF CONTENTS The Omega OM-CP-OCTPRO is a portable, multi-use industrial data logger with eight channels and a user-friendly touchscreen interface. This versatile logger measures and records 5 User Interface temperature, current, voltage and pulse simultaneously and displays data in real time. The...
  • Page 4 OM-CP-OCTPRO PRODUCT OVERVIEW Device Orientation The OM-CP-OCTPRO display can rotate 180 degrees depending on the desired orientation of the device. This option is available from the Settings menu under the Display section. Please note: Power restart required in order to apply screen rotation. Desktop Orientation Wall Mount Orientation For handheld and tabletop use, the inputs will be on the top.
  • Page 5 OM-CP-OCTPRO PRODUCT OVERVIEW Sensor Types & Measurement Ranges Each of the 8 input channels can be individually configured for the following types and sensor ranges. PARAMETER INPUT TYPE RANGE Current Current input -5 mA to 50 mA Frequency (port 1 only) Frequency input 0 to 25,000 Hz Pulse / Counter (port 1 only)
  • Page 6: User Interface

    OM-CP-OCTPRO USER INTERFACE Top Menu Bar The top bar of the OM-CP-OCTPRO Interface features status icons and useful information to refer to while using the device. Current Time Internal Memory External Logging Session Indicator Memory Battery Level 90% - 97% Full Alarm Set Inactive 97% - 100% Full...
  • Page 7 Press and hold the Power Button for Wait for the device to initiate, you will see 3 seconds to power up the device. the Omega logo when complete. SELECT SCREEN ORIENTATION SET UP INITIAL DATE AND TIME For desktop use, inputs are facing upward.
  • Page 8 OM-CP-OCTPRO USER INTERFACE Channel Configuration When the Channel Configuration icon is selected, the device will display the screen shown below • Channel 1-8: Configures the type of channel input, units, engineering units (if applicable), alarms and user calibration adjustments. • Update: Applies the current channel configuration to make the device ready to start logging or display real-time data.
  • Page 9 OM-CP-OCTPRO USER INTERFACE Measurement Setup When the user selects a Measurement Parameter, the device will display the relevant options for that selection. Example shown are the Voltage options. Select the Measurement button to display a pop-up screen of relevant measurement types to choose from. Select Channel Configuration Select Channel Select Measurement Parameter...
  • Page 10 OM-CP-OCTPRO USER INTERFACE Engineering Units Engineering Units can be applied to any channel measuring Voltage, Frequency or Pulse to display readings in a user selected custom unit of measure. • Gain: User selected gain value. • Offset: User selected offset value. •...
  • Page 11 OM-CP-OCTPRO USER INTERFACE Setting Up Engineering Units Click the Wizard button to launch the Engineering Unit Wizard. Enter the unit of measurement and abbreviation. The gain and offset are automatically set. Click Save to save Enter the low and high scale point inputs and outputs and click Apply.
  • Page 12 OM-CP-OCTPRO USER INTERFACE Keyboard Function When the user taps in any text field within the interface, the keyboard will appear. The numeric keypad appears when the Gain and Offset fields are selected. The keyboard appears when Unit of Measurement and Abbreviation fields are selected. To prevent the keyboard from obscuring content, the screen will always focus on the selected field and bring it into view.
  • Page 13 OM-CP-OCTPRO USER INTERFACE Factory Calibration The OM-CP-OCTPRO comes with a complete Factory Calibration and provides users the ability to adjust the calibration settings per channel, and roll back to the factory settings at any time. Note: For best performance and accuracy, Factory Calibration should be performed at least once every 12 months.
  • Page 14 OM-CP-OCTPRO USER INTERFACE Save Configuration Settings Load Configuration Settings Completed channel configurations can be saved for repeated Saved channel configurations can be easily loaded for repeated use. The user can select Save from the channel configuration use. The user can select File from the channel configuration screen screen to select a name for the saved settings file and apply them.
  • Page 15: Logging Data

    OM-CP-OCTPRO LOGGING DATA Start Logging When Start Logging is selected from the Home screen, the Logging Configuration screen will appear and the user will be prompted to name the data logging session. If the user has not already configured the channels, they will be prompted to configure prior to starting a logging session.
  • Page 16 OM-CP-OCTPRO LOGGING DATA Automatic Stop Selecting Automatic Stop will bring up the following configuration screen. • Day: Use the up and down arrows to adjust the day. • Hour: Use the up and down arrows to adjust the hour. • Minute: Use the up and down arrows to adjust the minute.
  • Page 17 OM-CP-OCTPRO LOGGING DATA Review Session Details and Start Logging Device Memory Warning Once the user selects a Session Name, Start Time, Stop Time and After selecting Start Logging, if the internal memory of the device Reading Rate, the screen will look similar as it does below. Once is 100% full, the user will be notified with a pop-up warning the settings are complete, the user will select Start Logging to message and two options to choose from.
  • Page 18: Viewing Data

    OM-CP-OCTPRO VIEWING DATA Real-Time Data When Real-Time is selected from the Home screen, the device will display data from all enabled channels and update at the user selected reading rates. The Real-time view is also available from the Current Session menu when the device is actively logging. •...
  • Page 19 OM-CP-OCTPRO VIEWING DATA Current Session — Tabular View Select the Current Session button from the Home screen to view the recorded data in various formats, swipe the screen to the left or right to navigate. • Displays the Minimum, Maximum and Average values for the current session.
  • Page 20: Managing Data

    OM-CP-OCTPRO MANAGING DATA Data Storage Selecting the Data Storage icon will bring up the screen pictured below. Stored sessions are displayed in a scrollable list, swipe vertically to browse the list. Session Information includes the name of the session, the start time and date of the session, and the number of readings.
  • Page 21 Note: Data can be saved to external memory as .csv and/or .mtb file format (user selectable in System/File Format). Saving as .mtb file format will allow data to be imported into Omega 4 Data Logger Software (version 4.2.13.0 or greater).
  • Page 22 OM-CP-OCTPRO MANAGING DATA View Data Sessions When the View Data option is selected, the user is presented with the Tabular Data view of that session. From this screen the user can swipe left and right to navigate other views of the recorded data from that session (see swipe navigation options on page 17). Select Data Storage Select a Session Select View Data...
  • Page 23 OM-CP-OCTPRO MANAGING DATA Delete Stored Session When the Delete session option is selected, the user is presented with a pop-up screen confirming the request. Deleting Stored Data Confirmation When Delete Data is selected a pop-up screen will display a progress bar and confirm when action is complete.
  • Page 24 OM-CP-OCTPRO MANAGING DATA No Stored Sessions Before first use or after all data has been deleted, the Data Storage screen on the device will resemble the screen shown below. Select Data Storage Product User Guide | 23...
  • Page 25: Device Settings

    Data from the Titan S8 can be saved to external memory in one of two formats. • USB Flash File Format: .csv spreadsheet, .mtb file (for import into Omega 4 Data Logger Software version 4.2.13.0 or greater) or both. • Data Logging File Readings Limit: Choose between 1 million or 5 million file readings limit.
  • Page 26 • Contact Signal: Pulse / Latch • Status: Shows if there are any alarms triggered. Help Power Provides Omega contact information to the user. Provides sleep mode, power off via screen and factory reset. Warning: Factory reset will restore the unit to Factory Settings.
  • Page 27: Specifications

    Battery may explode or fire if mistreated. Do not disassemble or dispose of in fire. Do not charge except specified with charging condition. Do not heat above 212 °F, or short circuit. Do not Specifications subject to change. See Omega’s terms and conditions at www.omega.com. crush or modify.
  • Page 28 OM-CP-OCTPRO SPECIFICATIONS Measurement Accuracy THERMOCOUPLE • At room temperature (25 after 60 minute °C ±10 °C) TYPE RANGE RESOLUTION ACCURACY warm-up period. -200 °C to +760 °C 0.1 °C ±0.5 °C • Temperature calibrated accuracy is thermocouple -270 °C to +1370 °C 0.1 °C ±0.5 °C dependent.
  • Page 29: Index

    OM-CP-OCTPRO INDEX Product Overview ............... 2 Viewing Data ..............17 Device Overview .................. 2 Real-Time Data ................... 17 External Features ................. 2 Current Session — Graph View ............17 Device Orientation ................3 Current Session — Tabular View ............. 18 Device Ports ..................3 Managing Data ..............19 Sensor Types &...
  • Page 30 Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA’s WARRANTY does not apply to defects resulting from any action of the purchas- er, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification.
  • Page 31 Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at omega.com TEMPERATURE M U Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies M U Wire: Thermocouple, RTD & Thermistor M U Calibrators & Ice Point References M U Recorders, Controllers &...