Sanyo STW-2 Series Owner's Manual

Sanyo STW-2 Series Owner's Manual

Packaged terminal air conditioner
Hide thumbs Also See for STW-2 Series:

Advertisement

OWNER'S MANUAL
PACKAGED TERMINAL AIR CONDITIONER
Contents
Alert Symbols ........................................................... 1
Installation Location ................................................ 2
Electrical Requirements .......................................... 2
Safety Instructions ................................................... 2
Names of Parts ......................................................... 2
Contents
IMPORTANT!
Please Read Before Starting ................................... 6
1.
NAMES OF PARTS............................................. 7
2.
WALL CASE AND REAR GRILLE ..................... 7
3.
INSTALLATION................................................... 7
4.
PERMANENT CONNECTION............................. 8
4-1. For 230/208V Units ...................................... 8
4-1-1. Preparation ........................................ 8
4-1-2. Installation.......................................... 8
4-2. For 265V Units ............................................. 8
4-2-1. Preparation ........................................ 8
4-2-2. Installation.......................................... 8
5.
AIR LOUVERS .................................................... 9
6.
TEMPERATURE LIMITING................................. 9
7.
REMOTE CONTROL ........................................ 10
8.
FRONT DESK CONTROL ................................ 10
PRODUCT INFORMATION ............................... 11
85164119653000
Operating Instructions
Page
Installation Instructions
Page
STW-2 Series
Front Grille ................................................................ 3
Other Features.......................................................... 3
Care and Cleaning.................................................... 4
Tips for Energy Saving ............................................ 5
Troubleshooting ....................................................... 5
Model No.
STW-2 Series
Power Source:
60 Hz, single-phase, 230/208V & 265V

Alert Symbols

The following symbols used in this manual alert you to potential-
ly dangerous conditions to users, service personnel or the appli-
ance:
This symbol refers to a hazard or
WARNING
unsafe practice which can result in
severe personal injury or death.
This symbol refers to a hazard or
CAUTION
unsafe practice which can result in
personal injury or product or prop-
erty damage.
SANYO Electric Co., Ltd.
Osaka, Japan
Cool / Heat Model
W
W

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo STW-2 Series

  • Page 1: Table Of Contents

    This symbol refers to a hazard or CAUTION unsafe practice which can result in personal injury or product or prop- erty damage. SANYO Electric Co., Ltd. Osaka, Japan Cool / Heat Model STW-2 Series...
  • Page 2: Installation Location

    2. Each unit must be properly grounded with a ground (or earth) wire or through the supply wiring. 3. Wiring must be done by a qualified electrician. 4. Never use an extention cord with this air conditioner. Safety Instructions • Read this Instruction Manual carefully before using this air conditioner.
  • Page 3: Front Grille

    This knob is set to CLOSE at the factory. When in this position, the vent door is closed and only indoor air is cir- culated by the air conditioner. Switching the knob to OPEN opens the vent door to allow outdoor air to enter the room.
  • Page 4: Care And Cleaning

    Push down NOTE Do not operate the air conditioner without the filters in place. If a filter becomes torn or damaged it should be replaced immediately. Operating the unit without the fil- ters in place or with damaged filters will allow dirt and dust to reach the indoor coil and reduce the efficiency of the unit.
  • Page 5: Tips For Energy Saving

    OR HEAT AS IT • Curtains, blinds or furniture blocking SHOULD” the front of the air conditioner are restricting the air flow. • Thermostat control may not be set high/low enough. Turn the control to a lower or higher position.
  • Page 6: Please Read Before Starting

    Replace them immediately. • DO NOT change the internal wiring or any part of the system. • DO NOT turn the air conditioner on and off by plugging and unplugging. Use the Operation switch (SELEC- TOR). • Follow National Electrical Code (NEC) and local codes, ordinances and regulations.
  • Page 7: Names Of Parts

    1. NAMES OF PARTS Rear grille/louver** Wall case** * Shipped with the chassis ** Check essential components list on chassis 2. WALL CASE AND REAR GRILLE 1) The STK01WC wall case must be properly installed according to the instructions packed with the case.
  • Page 8: Permanent Connection

    4-1-1. Preparation 1) The electrical rating marked on the previously installed air conditioner must be the same as the supply branch circuit. 2) The modification kit provides for connection of 1/2" trade size electrical conduit and connection to a wiring system in accordance with the National Electric Code, ANSI/NFPA No.
  • Page 9: Air Louvers

    3) Attach the field-supplied conduit to the bottom plate. 4) Connect the power supply conductors to the Terminal block and the Grounding screw. 5) Attach the cover plate. Cover plate 6) Reinstall the front grille. (See “Front Grille” on page 3.) 5.
  • Page 10: Remote Control

    Remote Control 7. REMOTE CONTROL The unit may be controlled either by the unit-mount- ed controls (Control Panel) or by optional Class 2 ther- mo controller (SC2001 for Cool/Heat Model and SC2201 for Heat Pump Model) with optional Interface kit (STK02LVC). Detailed instructions are included in the kit.
  • Page 11: Product Information

    Product Information If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate of the cabinet. Model No. Serial No. Date of purchase Dealer’s address Phone number...
  • Page 12 SANYO FISHER COMPANY A DIVISION OF SANYO NORTH AMERICA CORPORATION 21605 plummer Street, Chatsworth, CA 91311 U.S.A. In Canada SANYO Canada Inc. 300 Applewood Crescent, Concord, Ontario, L4K 5C7, Canada...

Table of Contents