Download Print this page

Sanyo 24KLS72 Submittal Data

Split system indoor/outdoor wall mounted low ambient air conditioner
Hide thumbs Also See for 24KLS72:

Advertisement

Split System Submittal Data
System: 24KLS72 Indoor/Outdoor: KS2472/CL2472
Wall Mounted Low Ambient Air Conditioner
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
(A)
Fuse Size, Max.
(A)
Compressor
No. used
R.L. Amps - L.R.
Crankcase Heater
(W)
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive - No. Speeds
No. Poles
(RPM)
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
(RPM, High)
No. Poles
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
(in.)
(in.)
Drain Connection Size
General Data (at 230/208V)
230/208/1/60
20
20
DC Rotary Inverter
(A)
9.6/10.9 - 17.5
Propeller
18 - 1/8 - 1
DC Motor
8 - 850
(W)
90 - 1
(A)
Aluminum Fin & Copper Pipe
Corrugated Plate - Inner Riff ed
2 - 18.1
(in.)
Cross Flow
3-11/16 33-9/32 - 1
3 & Auto
8 - 1250
(W)
30 - 1
600/541/482
(A)
Aluminum Plate Fin & Copper Tube
Slit Plate - Inner Riff ed
2 - 19.5
9/32"
23/32"
Approval:
Date:
Construction:
Unit #:
Drawing #:
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max
20
Lift Difference, Max
Line Size
Line Size
Dimensions
Indoor Unit
600
Outdoor Unit
0.7
Weight
Net
Shipping
6.4
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230V)
Cooling
Total Capacity
Sensible Capacity
Latent Capacity
SEER
Dehumidification
47
0.5
Amps
Power Inputs
Outdoor Sound Rating
3.07
Electric Expansion Valve
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
11-23/32 x 41-15/16 x 8-19/32
(Crated)
11-3/8 x 44-7/8 x 14-29/32
(Uncrated)
29-1/8 x 35-7/16 x 12-19/32
(Crated)
33-27/32 x 40-5/8 x 16-1/4
Indoor
(lbs.)
26.5
(lbs.)
33.1
Indoor
(cu.ft.)
4.23
(BTU/H)
24,200 (4,100-24,200)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
10.8/12.1(1.3-12.1)
(W)
2,355/2,355 (280-2,355)
(dB-A)
R410A
4.30
Flare
131
50
1/4"
5/8"
H x W x D
Outdoor
119
127.9
Outdoor
12.71
14,800
9,400
17
4.89
55

Advertisement

loading

Summary of Contents for Sanyo 24KLS72

  • Page 1 Split System Submittal Data System: 24KLS72 Indoor/Outdoor: KS2472/CL2472 Wall Mounted Low Ambient Air Conditioner Job Name: Location: Engineer: Submitted to: Submitted by: Reference: General Data (at 230/208V) Power V/PH/Hz Circuit Ampacity Fuse Size, Max. Compressor No. used R.L. Amps - L.R.
  • Page 2 Standard Available Available Available Indoor Air Intake Temp. Outdoor Air Intake Temp. 95F DB/71F WB 115F DB 67F DB/57F WB 0F DB Sanyo Commercial Solutions A Division of SANYO North America 1300 Michael Drive Wood Dale, IL 60191 USA www.sanyohvac.com...

This manual is also suitable for:

Ks2472Cl2472