Chicago Pneumatic CPF 175 Instruction Manual
Chicago Pneumatic CPF 175 Instruction Manual

Chicago Pneumatic CPF 175 Instruction Manual

Cp compressor
Hide thumbs Also See for CPF 175:
Table of Contents

Advertisement

Instruction Manual
CP COMPRESSOR
Model
CPF 200
CPF 175 - 200
CPVS 200 - 250
CPVS 250
EN
62 305 799 65

Advertisement

Table of Contents
loading

Summary of Contents for Chicago Pneumatic CPF 175

  • Page 1 Instruction Manual CP COMPRESSOR Model CPF 175 - 200 CPVS 200 - 250 62 305 799 65 CPF 200 CPVS 250...
  • Page 2 Chicago Pneumatic Compressors will decline any responsibility if these instructions are not respected. This equipment has been factory tested and satisfies normal operating conditions: they must not be exceeded as this would place the machine under abnormal stress and effort.
  • Page 3: Cpvs

    WARNING: the operation connection cables between the different elements must never follow the same path as the existing power cords. A separate installation from the power cords must be carried out. • Install an RC filter on all the relay coils of the external operation units. 11/2008 Chicago Pneumatic Compressors Page 3 62 305 799 65...
  • Page 4: Table Of Contents

    CONTENTS Space requirement and installation diagram CPF 175 - CPVS 200 (Air cooled) ................6 Space requirement and installation diagram CPF 200 - CPVS 250 (Air cooled) ................7 Chapter 1 - Description ....................................8 A - General Information ..................................8 B - Respect of the environment and prevention of pollution ......................
  • Page 5 CONTENTS Chapter 8 - Trouble shooting ..................................25 A - Main incidents .................................... 25 11/2008 Chicago Pneumatic Compressors Page 5 62 305 799 65...
  • Page 6: Space Requirement And Installation Diagram Cpf 175 - Cpvs 200 (Air Cooled)

    Space requirement and installation diagram CPF 175 - CPVS 200 (Air cooled) (see page 2 - installation instructions) Fig. 1 9.52 4.76 30.19 24.56 58.66 98.58 Air inlet side Air delivery Cooling air outlet 22.99 3.34 3.34 Dimensions for outlet duct 3.14...
  • Page 7: Space Requirement And Installation Diagram Cpf 200 - Cpvs 250 (Air Cooled)

    Cooling air outlet 1.14 0.33 0.33 Dimensions for outlet duct 29.33 24.64 24.64 Electric power diam. 1.88x3 + 2.83 diam. 1.45 4.33 Ø0.78 0.39 1.96 3.54 25.98 33.07 * Hole 0.32x0.32 11/2008 Chicago Pneumatic Compressors Page 7 62 305 799 65...
  • Page 8: Chapter 1 - Description

    3. An air temperature sensor that stops the compressor when The Chicago Pneumatic Compressors air compressor CPF, CPVS the temperature rises abnormally or during an oil cooling model, constitute a central compressed air which is fully equipped defect.
  • Page 9: Chapter 2 - Installation

    D - Air discharge pipes The diameter of the air discharge pipe must be at least 3" gas for the CPF 175/200 and CPVS 200/250.Current legislation requires Ventilation Duct minimum cross section that a valve which is lockable in the closed position be installed ( d ≤...
  • Page 10: E - Electric Cabling

    CP unit. • The electric current must be cut whenever maintenance work is carried out on the machine (except for pressurized oil change) NOTE For variable speed machines see Chapter 6. 11/2008 Chicago Pneumatic Compressors Page 10 62 305 799 65...
  • Page 11: Chapter 3 - Commissioning

    "class B" and in presence of a live electrical conductor, it is recommended to use a CO2 extinguisher functioning by "smothering" (starvation of oxygen) while observing the user instructions applicable to the model. Fig. 9 11/2008 Chicago Pneumatic Compressors Page 11 62 305 799 65...
  • Page 12: Chapter 4 - Operation

    (Item. 49). The remaining oil, which is separated by the last stage of the oil separator, is drawn up by a dip tube and dispatched to the compressor. Fig. 10 - Air / oil circuit 11/2008 Chicago Pneumatic Compressors Page 12 62 305 799 65...
  • Page 13: B - Regulation Principles

    1 - "On/off Load" regulation (see Fig. 11) standard version Compressor Suction housing The CPF 175-200 units are fitted with an automatic regulation Solenoid-valve system, enabling the machine to be stopped after it has run unloaded for a given (adjustable) period of time. This period of...
  • Page 14: Chapter 5 - Options

    (Fig. 13a and 13b). Fig. 12 Extraction duct VORTEX pre-filter Air filter 1 - Condensation intake 4 - Main duct CPF 175 2 - Capacitive sensor 5 - Electric valve 98,58 16,9 CPVS 200 3 - Receiver...
  • Page 15: C - Pre-Filtration Panels (Fig. 14 And 15)

    Dimensions : Width : 49,7 in 56,7 in Length : 66,1 in 72,8 in Thickness : 9,5 in 9,5 in This option may be installed on a compressor already in place. 11/2008 Chicago Pneumatic Compressors Page 15 62 305 799 65...
  • Page 16: D -Automatic Restarting

    THIS OPERATION REQUIRES THE CONFIGURA- TION OF MENUS IN THE CONTROLLER, ACCESS RESTRICTED TO TECHNICIANS CERTIFIED BY CHICAGO PNEUMATIC COMPRESSORS AN INFORMATIVE INSERT MUST BE PLACED ON THE ELECTRIC CABINET TO WARN THE USER OF THE RISK THAT THE COMPRESSOR MAY AUTOMATICALLY RESTART AT ANY TIME.
  • Page 17: Chapter 6 - Specific Information For Cpvs 200 - 250

    The connection of the power supply to the section switch also the case for the other I/O control terminals, even • (if present) requires the use of properly insulated terminals. if switch X4 is in the OFF position (Stop). 11/2008 Chicago Pneumatic Compressors Page 17 62 305 799 65...
  • Page 18: D - Commissioning

    "Set point 1". In this way, the current used by the compressor changes in consumption (changes in the flow-rate). is minimised (see notice AIRLOGIC). Do not set the stop pressure at a level beyond the machine's max P. 11/2008 Chicago Pneumatic Compressors Page 18 62 305 799 65...
  • Page 19 The pressure then rises again and the cycle starts over (fig. 20d). To avoid pumping the system - frequent stop / start - drainage time may be increased (cf. notice AIRLOGIC). 11/2008 Chicago Pneumatic Compressors Page 19 62 305 799 65...
  • Page 20: E - Operating Incidents

    The main incidents likely to occur are listed below, along with the remedies to be applied. The keys to the control lamps relate to the instrument panel (refer to the AIRLOGIC Manual). 11/2008 Chicago Pneumatic Compressors Page 20 62 305 799 65...
  • Page 21: Chapter 7 - Maintenance

    - viscosity index: 90 minimum The spent oil that remains in the compressor may contaminate the - antioxidant additives oil system. - anti-rust additives It is strongly recommended to use Chicago Pneumatic - anti-foam additives Compressors oil. 11/2008 Chicago Pneumatic Compressors...
  • Page 22: B - Oil Return (Fig. 22)

    • Reseal the filler cap when replacing it and check that all openings This Rotair Xtra oil was specially designed for Chicago Pneumatic are properly closed. Compressors and guarantees to the operator an oil change period • The machine can be restarted only after pressing the button C of 2000 hours, with the replacement of the oil separator filter several times to return to STATE 0.1.
  • Page 23: D - Fan

    - apply a tightening torque of 15 m-kg to tighten the cover screws, - re-screw the flange onto the cooler, - connect the regulation system and oil return, - refit the "VICTAULIC" union. 11/2008 Chicago Pneumatic Compressors Page 23 62 305 799 65...
  • Page 24: G - Draining Condensation Water (See B Chapter 1)

    Perfect alignment is obtained automatically thanks to the cen- tring bell between the compressor and the motor. WARNING The retainer locks of the two shafts must be positioned at 180° from each other for proper balance. 11/2008 Chicago Pneumatic Compressors Page 24 62 305 799 65...
  • Page 25: Chapter 8 - Trouble Shooting

    Remove retainer blocks. not removed. 9. THE COMPRESSOR STOPS a) Electromagnetic disturbance a) Add an interference suppression kit RANDOMELY OR CREATES on the electronic controler. (contact the after sales department) NON-EXISTING FAULTS 11/2008 Chicago Pneumatic Compressors Page 25 62 305 799 65...
  • Page 26: 11/2008 Chicago Pneumatic Compressors

    NOTE 11/2008 Chicago Pneumatic Compressors Page 26 62 305 799 65...
  • Page 27: 11/2008 Chicago Pneumatic Compressors

    11/2008 Chicago Pneumatic Compressors Page 27 62 305 799 65...
  • Page 28 support support@CPcompressor.com 1 - 877 - 861 - CPAC CP Compressors 1800 Overview Dr Rock Hill, SC 29730...

This manual is also suitable for:

Cpf 200Cpvs 200Cpvs 250

Table of Contents