Chicago Pneumatic Compressors will decline any responsibility if these instructions are not respected. This equipment has been factory tested and satisfies normal operating conditions: they must not be exceeded as this would place the machine under abnormal stress and effort.
WARNING: the operation connection cables between the different elements must never follow the same path as the existing power cords. A separate installation from the power cords must be carried out. • Install an RC filter on all the relay coils of the external operation units. 11/2008 Chicago Pneumatic Compressors Page 3 62 305 799 65...
CONTENTS Space requirement and installation diagram CPF 175 - CPVS 200 (Air cooled) ................6 Space requirement and installation diagram CPF 200 - CPVS 250 (Air cooled) ................7 Chapter 1 - Description ....................................8 A - General Information ..................................8 B - Respect of the environment and prevention of pollution ......................
Page 5
CONTENTS Chapter 8 - Trouble shooting ..................................25 A - Main incidents .................................... 25 11/2008 Chicago Pneumatic Compressors Page 5 62 305 799 65...
3. An air temperature sensor that stops the compressor when The Chicago Pneumatic Compressors air compressor CPF, CPVS the temperature rises abnormally or during an oil cooling model, constitute a central compressed air which is fully equipped defect.
D - Air discharge pipes The diameter of the air discharge pipe must be at least 3" gas for the CPF 175/200 and CPVS 200/250.Current legislation requires Ventilation Duct minimum cross section that a valve which is lockable in the closed position be installed ( d ≤...
CP unit. • The electric current must be cut whenever maintenance work is carried out on the machine (except for pressurized oil change) NOTE For variable speed machines see Chapter 6. 11/2008 Chicago Pneumatic Compressors Page 10 62 305 799 65...
"class B" and in presence of a live electrical conductor, it is recommended to use a CO2 extinguisher functioning by "smothering" (starvation of oxygen) while observing the user instructions applicable to the model. Fig. 9 11/2008 Chicago Pneumatic Compressors Page 11 62 305 799 65...
(Item. 49). The remaining oil, which is separated by the last stage of the oil separator, is drawn up by a dip tube and dispatched to the compressor. Fig. 10 - Air / oil circuit 11/2008 Chicago Pneumatic Compressors Page 12 62 305 799 65...
1 - "On/off Load" regulation (see Fig. 11) standard version Compressor Suction housing The CPF 175-200 units are fitted with an automatic regulation Solenoid-valve system, enabling the machine to be stopped after it has run unloaded for a given (adjustable) period of time. This period of...
Dimensions : Width : 49,7 in 56,7 in Length : 66,1 in 72,8 in Thickness : 9,5 in 9,5 in This option may be installed on a compressor already in place. 11/2008 Chicago Pneumatic Compressors Page 15 62 305 799 65...
THIS OPERATION REQUIRES THE CONFIGURA- TION OF MENUS IN THE CONTROLLER, ACCESS RESTRICTED TO TECHNICIANS CERTIFIED BY CHICAGO PNEUMATIC COMPRESSORS AN INFORMATIVE INSERT MUST BE PLACED ON THE ELECTRIC CABINET TO WARN THE USER OF THE RISK THAT THE COMPRESSOR MAY AUTOMATICALLY RESTART AT ANY TIME.
The connection of the power supply to the section switch also the case for the other I/O control terminals, even • (if present) requires the use of properly insulated terminals. if switch X4 is in the OFF position (Stop). 11/2008 Chicago Pneumatic Compressors Page 17 62 305 799 65...
"Set point 1". In this way, the current used by the compressor changes in consumption (changes in the flow-rate). is minimised (see notice AIRLOGIC). Do not set the stop pressure at a level beyond the machine's max P. 11/2008 Chicago Pneumatic Compressors Page 18 62 305 799 65...
Page 19
The pressure then rises again and the cycle starts over (fig. 20d). To avoid pumping the system - frequent stop / start - drainage time may be increased (cf. notice AIRLOGIC). 11/2008 Chicago Pneumatic Compressors Page 19 62 305 799 65...
The main incidents likely to occur are listed below, along with the remedies to be applied. The keys to the control lamps relate to the instrument panel (refer to the AIRLOGIC Manual). 11/2008 Chicago Pneumatic Compressors Page 20 62 305 799 65...
- viscosity index: 90 minimum The spent oil that remains in the compressor may contaminate the - antioxidant additives oil system. - anti-rust additives It is strongly recommended to use Chicago Pneumatic - anti-foam additives Compressors oil. 11/2008 Chicago Pneumatic Compressors...
• Reseal the filler cap when replacing it and check that all openings This Rotair Xtra oil was specially designed for Chicago Pneumatic are properly closed. Compressors and guarantees to the operator an oil change period • The machine can be restarted only after pressing the button C of 2000 hours, with the replacement of the oil separator filter several times to return to STATE 0.1.
- apply a tightening torque of 15 m-kg to tighten the cover screws, - re-screw the flange onto the cooler, - connect the regulation system and oil return, - refit the "VICTAULIC" union. 11/2008 Chicago Pneumatic Compressors Page 23 62 305 799 65...
Perfect alignment is obtained automatically thanks to the cen- tring bell between the compressor and the motor. WARNING The retainer locks of the two shafts must be positioned at 180° from each other for proper balance. 11/2008 Chicago Pneumatic Compressors Page 24 62 305 799 65...
Remove retainer blocks. not removed. 9. THE COMPRESSOR STOPS a) Electromagnetic disturbance a) Add an interference suppression kit RANDOMELY OR CREATES on the electronic controler. (contact the after sales department) NON-EXISTING FAULTS 11/2008 Chicago Pneumatic Compressors Page 25 62 305 799 65...