Download Print this page

Agilent Technologies IMG-300 Instruction Manual

Inverted magnetron gauge

Advertisement

Quick Links

www.idealvac.com
(505)872-0037
IMG-300 Inverted
Magnetron Gauge
Manual No. 699908230
Revision A
March 2009
NOTICE: This document contains references to Varian.
Please note that Varian, Inc. is now part of Agilent
Technologies. For more information, go to
www.agilent.com/chem.
vacuum technologies
INSTRUCTION MANUAL

Advertisement

loading

Summary of Contents for Agilent Technologies IMG-300

  • Page 1 NOTICE: This document contains references to Varian. www.idealvac.com Please note that Varian, Inc. is now part of Agilent Technologies. For more information, go to www.agilent.com/chem. (505)872-0037 vacuum technologies IMG-300 Inverted INSTRUCTION MANUAL Magnetron Gauge Manual No. 699908230 Revision A March 2009...
  • Page 2 IMG-300 Inverted Magnetron Gauge Copyright 2009 Varian, Inc.
  • Page 3 IMG-300 Inverted Magnetron Gauge Warranty Products manufactured by Seller are warranted against defects in materials and workmanship for twelve (12) months from date of shipment thereof to Customer, and Seller’s liability under valid warranty claims is limited, at the option of Seller, to repair, replace, or refund an equitable portion of the purchase price of the Product.
  • Page 4 IMG-300 Inverted Magnetron Gauge This page intentionally left blank.
  • Page 5: Table Of Contents

    IMG-300 Inverted Magnetron Gauge Contents Preface ............................viii Hazard and Safety Information....................viii IMG-300 General Purpose Inverted Magnetron Gauge .............. 1-1 Description ..........................1-1 Application ..........................1-1 Technical Specifications ......................1-3 Ordering Information ........................1-3 Fringe Field Contours........................1-4...
  • Page 6 IMG-300 Inverted Magnetron Gauge This page intentionally left blank.
  • Page 7 IMG-300 Inverted Magnetron Gauge to which this declaration relates is in conformity with the following standard(s) or other normative documents. auf das sich diese Erklärung bezieht, mit der/den flogenden Norm(en) oder Richtlinie(n) übereinstimmt.
  • Page 8: Preface

    IMG-300 Inverted Magnetron Gauge Preface Hazard and Safety Information This product must only be operated and maintained by trained personnel. This manual uses the following standard safety protocols: WARNING Warnings indicate a particular procedure or practice, which if not followed correctly, could lead to serious injury.
  • Page 9 IMG-300 Inverted Magnetron Gauge Grounding the IMG-300 Inverted Magnetron Gauge Controller Be certain that the IMG-300 Inverted Magnetron Gauge Controller and vacuum system are separately connected to a common ground. ❑ WARNING Do not place a ground wire between the vacuum chamber and the controller chassis;...
  • Page 10 IMG-300 Inverted Magnetron Gauge Vacuum Equipment and Cleanliness Cleanliness is vital when servicing any vacuum equipment. CAUTION Do not use silicone oil or silicone grease. Use powder-free butyl or polycarbonate gloves to prevent skin oils from getting on vacuum surfaces.
  • Page 11 IMG-300 Inverted Magnetron Gauge EMC Warnings EN 55022 Class A Warning This is a Class A product. In a domestic environment this product may cause radio interference. In such cases, the user will be required to correct the interference at his own expense.
  • Page 12 IMG-300 Inverted Magnetron Gauge This page intentionally left blank.
  • Page 13: Img-300 General Purpose Inverted Magnetron Gauge

    While the inverted magnetron design ensures good linearity as compared to a standard cold cathode type gauge, the IMG-300, like other cold cathode type gauges, is generally not as stable and linear as a well-maintained Bayard-Alpert type.
  • Page 14 Do not mount the IMG-300 closer than a few inches to any magnetic material. ❑ If no magnetic force from the IMG-300 can be felt, it is sufficiently far away. ❑ Exercise care in mounting and handling to prevent the gauge from contacting other objects, especially steel hand tools as these are strongly attracted by the magnet.
  • Page 15: Technical Specifications

    < 10 milliseconds for increasing pressure Material Exposed to the Vacuum 304L Stainless steel, Nickel, 2% Thoriated Tungsten, and ceramic Ordering Information Table 1-2 lists the part numbers for the IMG-300. Table 1-2 IMG-300 Parts Part Number Description R0343301 IMG-300 2.75 CFF...
  • Page 16: Fringe Field Contours

    IMG-300 Inverted Magnetron Gauge Fringe Field Contours Figure 1-2 and Figure 1-3 represent fringe field contours. Figure 1-2 Fringe Field Contour...
  • Page 17 IMG-300 Inverted Magnetron Gauge Figure 1-3 Fringe Field Contour...
  • Page 18 IMG-300 Inverted Magnetron Gauge This page intentionally left blank.
  • Page 19 IMPORTANT Instructions for returning products Dear Customer, Please follow these instructions whenever one of our products needs to be returned: 1. Complete the Request for Return form on our website (www.varianinc.com) and send it to Varian (see below), taking particular care to identify all products that have pumped or been exposed to any toxic or hazardous materials.
  • Page 20 IMG-300 Inverted Magnetron Gauge This page intentionally left blank.
  • Page 22 Sales and Service Offices Canada Italy United States Central coordination through: Varian, Inc. Varian, Inc Varian, Inc. via F.lli Varian 54 121 Hartwell Avenue 121 Hartwell Avenue 10040 Leini, (Torino) Lexington, MA 02421 Lexington, MA 02421 Italy Tel.: +39 011 997 9111 Tel.: +1 781 861 7200 Tel.: +1 781 861 7200 Toll-Free: 00 800 234 234 00...