Download Print this page
Honeywell DT7550UK2 DUAL TEC Installation Instructions

Honeywell DT7550UK2 DUAL TEC Installation Instructions

With anti-mask motion sensor

Advertisement

Quick Links

Select the mounting location.

Mounting Location Guidelines
• 2.3 m mounting height.
• Avoid direct or reflected sunlight.
• Aim sensor away from windows, heating/cooling devices
or large moving objects.
• Sensor must have a clear line-of-sight to protected area.

Wire the unit.

• Connect wires as shown using 0.2 - 1.3 mm
2
wire size.
Observe proper polarity.
• If not using the integrated EOL resistors, remove jumpers from
all pins.
• If using the integrated EOL resistors:
1. Connect the sensor to the panel (see wiring diagrams on
the right; if using the two loop option, also cut link W1).
2. Place the jumpers on the appropriate fault, tamper and
alarm pin options (see table below).
Notes:
• Consult the Control Panel manual to determine proper EOL
selection.
• Fit only one jumper each for the fault, tamper and alarm
EOL settings.
Jumper Position EOL Value
FAULT
E
2.2K
(RF)
F
3K
A
1K
TAMPER
B
2.2K
(RT)
C
4.7K
D
5.6K
1K
A
Factory default
2.2K
B
settings are
ALARM
shown in grey.
(RA)
4.7K
C
D
5.6K
Separate the sensor housings and remove the
printed circuit board (PCB).
For improved anti-mask
performance the look-down
mirror is disabled. To enable
look-down remove the mask.
• Use a small screwdriver to unfasten the housing latch. Gently pull
apart the housings.
• Push outward on the PCB latch and lift the PCB out of the housing.
Fault, Alarm and Tamper configured to one loop.
Fault, Alarm and Tamper configured to two loops.

Mount the unit.

Rear Tamper Breakaway
Tab: Best if mounted to a
Note: The cover screw,
stud, solid wood, or with
when used, is installed
a robust wall anchor.
here.
*Note: If the Rear
Tamper function is not
required, do not use the
mounting holes in the
Rear Tamper Breakaway
Tab.
• Slide the wire through the wire channel in the back housing.
• Mount the back housing flat against a wall or in a corner.
• Replace the PCB.

Walk-test the sensor.

a
50%
75%
100%
25%
• Apply power to the unit. Initialisation is complete when the
LED stops flashing slowly.
• Adjust the microwave range to minimum setting (25%) by
turning the range adjustment counterclockwise using a
small screwdriver.
• Replace the front housing.
• Begin walking through the detection area.
- The LED will turn red, indicating an alarm detection.
• Increase the microwave range as necessary.
• Repeat the items in step 5a until proper detection range is
obtained.
• The sensor MUST be walk tested after every power up
to complete the power up mask detection test.
Corner
Mount Hole*
Wall
Mount
Holes
Wire Channel
Note: If using the Rear Tamper feature, refer to the Rear Tamper
section before mounting the sensor.
Optional: Walk-test using Zone Finder.
b
Use the Zone Finder mode to identify the PIR and/or
microwave pattern. In Zone Finder mode the red
LED is disabled.
• Use a screwdriver to short the test pads.
• During the Zone Finder walk-test mode, the LED turns:
- green for one second for every PIR detection;
- yellow for two seconds for every microwave detec-
tion.
• Adjust the microwave range as necessary.
• Zone finder mode times out after ten minutes.
Corner
Mount
Holes

Advertisement

loading

Summary of Contents for Honeywell DT7550UK2 DUAL TEC

  • Page 1 ❶ ❷ ❸ Select the mounting location. Separate the sensor housings and remove the Mount the unit. printed circuit board (PCB). Rear Tamper Breakaway Tab: Best if mounted to a Note: The cover screw, stud, solid wood, or with when used, is installed a robust wall anchor.
  • Page 2 11.9 cm H x 7.1 cm W x 4.2 cm D © 2008 Honeywell International Inc. • Honeywell, IntelliSense and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved.