Checking Alarms Using the ICIM,
Alarm Threshold Values
Alarm threshold is the value at which an alarm is triggered. The alarm threshold
data for the modules are shown below.
FHEDA Alarm Threshold Value Parameters
Alarm
Display
RfIn
RfOut
PsOk
IHybd1
IHybd2
Enable
RHEDA Alarm Threshold Value Parameters
Alarm
Display
RfIn
RfOut
PsOk
IHybd
Enable
78-4006323-01 Rev C
Continued
Major
Minor
Low Limit
Low Limit
-15.0 dB
-7.0 dB
-15.0 dB
-7.0 dB
N/A
N/A
0.050A
0.100A
0.200A
0.250A
N/A
N/A
Major
Minor
Low Limit
Low Limit
-15.0 dB
-7.0 dB
-15.0 dB
-7.0 dB
N/A
N/A
0.050A
0.100A
N/A
N/A
Operation Using ICIM
Minor
Major
High Limit
High Limit
7.0 dB
15.0 dB
7.0 dB
15.0 dB
N/A
N/A
0.300A
0.350A
0.550A
0.600A
N/A
N/A
Minor
Major
High Limit
High Limit
7.0 dB
15.0 dB
7.0 dB
15.0 dB
N/A
N/A
0.300A
0.350A
N/A
N/A
Hysterisis
1.0 dB
1.0 dB
N/A
0.001A
0.001A
N/A
Hysterisis
1.0 dB
1.0 dB
N/A
0.001A
N/A
3-27