Appendix A - Normal Menu / Setup Menu - GE Masoneilan 12420 Instruction Manual & Safety Manual

Masoneilan 12400 series. level transmitter/controller
Table of Contents

Advertisement

APPENDIX A
SCREEN DESCRIPTION FOR NORMAL MENU
→ NORMAL
↓ SETUP
↓ CONTROLLER SETPOINT
VIEW DATA
VIEW ERRORS
CLEAR ERRORS
SCREEN DESCRIPTION FOR SETUP MENU
BASIC SETUP
ADVANCED SETUP
NORMAL
VIEW DATA
VIEW ERRORS
CLEAR ERRORS
Note on pushbuttons lock:
Access to main functions can be locked using the hardware lock jumper, located in the front view of the instrument head,
behind the main cover, or by software activation (with ValVue software or a HART handled terminal).
When set to the secure position, shorting the two-pin header, no change of setting parameter is allowed (no access to
Setup and Clear Errors menus). It is not allowed to write any new data into the instrument memory. Pushbuttons, ValVue
and any HART
handheld are locked out, except to read data (normal, view data and view errors menus). In such case,
®
LOCK message is indicated on LCD display when user presses a button.
This hardware lock jumper must be set in the secure (locked) position to be used as a SIL 2 instrument.
® 2014 General Electric Company. All rights reserved.
In Normal Mode, the screen displays in sequence the value of the level and of the output
current. Validate by pressing the * to stay in Normal mode.
Validate by pressing the * to enter the Setup Menu.
Validate by pressing the * to set the setpoint of the control loop. This feature is displayed
only if the instrument is a Level Controller (12410 model only).
Validate by pressing the * to enter the View Data Menu.
Validate by pressing the * to read eventual error indication(s) since last clear of errors.
Validate by pressing the * to clear error message(s) saved in memory.
Validate by pressing the * to enter the Basic Setup Menu.
Validate by pressing the * to enter the Advanced Setup Menu.
Validate by pressing the * to return to Normal Menu. In Normal Mode, the screen displays
in sequence the value of the level and of the output current.
Validate by pressing the * to enter the View Data Menu.
Validate by pressing the * to read eventual error indication(s) since last clear of errors.
Validate by pressing the * to clear error message(s) saved in memory.
Masoneilan 12400 Series Transmitter/Controller Instruction Manual | 61