248669 Conversion Kit
Convert and phase E-XP2 to an E-30 with 15.3kW of
heat by changing pump lowers, bearings, and changing
the Motor Control DIP settings to that of an E-30. For
removal and installation of pump lowers and bearings,
see Pump Removal, page 24. For changing Motor Con-
trol DIP settings, see Motor Control Board, page 34.
303
316
306B
65
72
Ref.
No.
Part No. Description
65
118463
ELBOW, swivel; 3/4 npt(m) x 1 in. npt(f)
303
245927
HOUSING, bearing
306A 246832
PUMP, displacement, component A;
see 309557
306B 245972
PUMP, displacement, component B;
see 309577
316
193394
NUT, retaining
Reactor Assembly
Qty
2
2
1
1
2
306A
245981 Motor
Control Board
DIP Switch
(SW2) need to
be set for an
E-30. 1,2,3, ON -
4 OFF. See page
34.
tI5121a
309574L