Download Print this page

Hanna Instruments HI 99191 Instruction Manual

Portable waterproof ph / temperature meter for drinking water analysis

Advertisement

Quick Links

Instruction Manual
HI 99191
Portable Waterproof pH / Temperature
Meter for Drinking Water Analysis
WARRANTY
HI 99191 is guaranteed for two years against defects in
workmanship and materials when used for their intended
purpose and maintained according to instructions. The electrodes
are guaranteed for a period of six months. This warranty is
limited to repair or replacement free of charge. Damage due to
accidents, misuse, tampering or lack of prescribed maintenance
is not covered.
If service is required, contact the dealer from whom you
purchased the instrument. If under warranty, report the
model number, date of purchase, serial number and the
nature of the problem. If the repair is not covered by the
warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain
a Returned Goods Authorization number from the Technical Service
department and then send it with shipping costs prepaid.
When shipping any instrument, make sure it is properly
packaged for complete protection.
All rights are reserved. Reproduction in whole or in part is
prohibited without the written consent of the copyright owner.
Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using this
instrument. This manual will provide you with the necessary
information for correct use of these instruments, as well as a
precise idea of their versatility. If you need additional technical
information, do not hesitate to e-mail us at
tech@hannainst.com or view our worldwide contact list at
www.hannainst.com.
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine
it carefully to make sure that no damage has occurred during
shipment. If noticeable damage is evident, notify your dealer.
Note: Save all packing material until you are sure that the
instrument functions correctly. All defective items must be
returned in the original packing together with the
supplied accessories.
GENERAL DESCRIPTION
HI 99191 is a portable, microprocessor-based pH and temperature
meter specifically designed for Drinking Water Analysis.
Main features include: waterproof and compact casing; large
dual-line display; low battery detection; automatic pH calibration
at one or two points within two memorized buffer sets
(standard or NIST); selectable temperature unit (°C or °F).
The pH electrode has a built-in temperature sensor for simultaneous
temperature compensated pH and temperature readings, and
also contains an integral pH sensor preamplifier to provide
measurements impervious to noise and electrical interferences.
FC 215D pH electrode with a built-in temperature sensor,
features a rugged, easy to clean, PVDF body and a special
sensitive glass membrane which allows a quick response time in
low conductivity samples as drinking water is.
Each meter is supplied with:
• FC 215D pH electrode with internal temperature sensor, for
Drinking Water Analysis, with DIN connector and 1 m (3.3')
cable
• pH 4.01 & pH 7.01 buffer sachets
• HI 700661 electrode cleaning solution (2x20 mL)
• 3 x 1.5V AAA batteries
• rugged carrying case
• instruction manual
LCD DESCRIPTION
1. Automatic Temperature Compensation indicator
2. Battery percentage (visible at power up)
3. Secondary display
4. Low battery indicator
5. Stability indicator
6. pH calibration indicator
7. Selectable temperature unit
8. Primary display
9. Measuring unit for primary display
ACCESSORIES
FC 215D
pH electrode with internal temperature sensor, for
Drinking Water Analysis, with DIN connector and 1 m
(3.3') cable
HI 7004L
pH 4.01 buffer solution, 500 mL
HI 7006L
pH 6.86 buffer solution, 500 mL
HI 7007L
pH 7.01 buffer solution, 500 mL
HI 7009L
pH 9.18 buffer solution, 500 mL
HI 7010L
pH 10.01 buffer solution, 500 mL
HI 70300L pH electrode Storage solution, 500 mL
HI 7061L
pH electrode Cleaning solution, 500 mL
HI 70630L pH electrode Acid Cleaning solution 500 mL
HI 70631L pH electrode Alkaline Cleaning solution, 500 mL
HI 70632L pH electrode Cleaning and Disinfection solution, 500 mL
HI 7071
Refilling Solution
SPECIFICATIONS
Range (*)
-2.00 to 16.00 pH
-5.0 to 105.0 °C / 23.0 to 221.0 °F
Resolution
0.01 pH
0.1 °C / 0.1 °F
Accuracy
±0.02 pH
(@25 °C/77 °F)
±0.5 °C up to 60 °C; ±1.0 °C outside
±1.0 °F up to 140 °F; ±2.0 °F outside
Temperature Compensation
Automatic
pH Calibration
Automatic, 1 or 2 point
choose between 2 sets of buffers
(standard: 4.01/7.01/10.01 or NIST: 4.01/6.86/9.18)
Probe (included)
preamplified pH/temperature
probe with DIN connector and 1 m (3.3') cable
Battery Type
3 x 1.5V AAA
Battery Life
Approximately 1200 hours of continuous use
Auto-off
After 8 minutes of non-use
Environment
0 to 50 °C (32 to 122 °F);
RH max. 100%
Dimensions
152 x 58 x 30 mm (6.0 x 2.3 x 1.2")
Weight
205 g (7.2 oz.)
(*) the temperature range is limited from 0 to 50 °C (32 to
122 °F) when using FC 215D sensor.
To clean the meter, use water only.
Hanna Instruments reserves the right to modify the design,
construction or appearance of its products without advance
notice.
IST99191 06/13
FC 215D

Advertisement

loading

Summary of Contents for Hanna Instruments HI 99191

  • Page 1 Dimensions 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”) HI 99191 is guaranteed for two years against defects in (standard or NIST); selectable temperature unit (°C or °F). Weight 205 g (7.2 oz.)
  • Page 2 OPERATIONAL GUIDE pH MEASUREMENT & CALIBRATION METER SETUP First time you use the instrument open the battery compartment • Make sure the meter has been calibrated before use. If a single-point calibration with buffers pH 7.01 or 6.86 is Setup mode allows the selection of the temperature unit and the •...